Prior to installation
For optimum extractor hood efficiency:
Short, smooth air exhaust pipe.
As few bends in the pipe as possible.
Diameter of pipe to be as large as
possible and no tight bends in pipe.
If long, rough exhaust-air pipes,
many pipe bends or smaller pipe
diameters are used, the air extraction
rate will no longer be at an optimum
level and there will be an increase in
noise.
Round pipes:
We recommend
Internal diameter: 150 mm (at least
120 mm).
Flat ducts must have an internal cross-
section that equates to that of round
pipes.
There should be no sharp bends.
l 120 mm approx. 113 cm
l 150 mm approx. 177 cm
If pipes have different diameters:
Insert sealing strip.
For exhaust-air mode, ensure that
there is an adequate supply of fresh air.
Connecting a l 150 mm exhaust-air
pipe:
Mount the pipe directly onto the air
outlet on the hood.
Connecting a l 120 mm exhaust-air
pipe:
Place the reducing connecting piece
onto the air connecting piece – Fig. 3 –
and fasten the exhaust pipe to it.
Attach the exhaust-air pipe to the
reducing connector.
10
Circulating-air mode
circulating-air mode, you can purchase the
complete installation set at specialist
outlets.
Preparing the wall
Weight in kg:
2
2
DWC041650
DWC046750
DWC041650B
LC457CA60B
We reserve the right to construction changes within the
context of technical development.
With activated carbon filter if exhaust-air
mode is not possible.
If the extractor hood is suitable for
The wall must be flat and perpendicular.
Ensure that the wall is capable of
providing a firm hold for mounting
screws and plugs.
Exhaust
air
15
20
LC457CA60
20
20
D94K55N0
15
15
LC456CA30
20
15
3BC845
20
3BC847
Fig. 4
Recircula-
ting air
17
22
22
22
17
17
22
17
22