The outputs will be deactivated and the UP or DOWN operation LED will blink rapidly to indicate the learning mode. The LEDs of the
learned push buttons will blink rapidly as well. You can easily detect which push buttons have been learned for the UP or DOWN con-
trol. Add a specific push button by maintaining it pressed until the output activates. Releasing the push button will deactivate the output
while the indication LED of the push button blinks rapidly as confirmation. You can not add any more push buttons when the maximum
number of push buttons has been reached.
A learned push button can be deleted by maintaining it pressed. Releasing it will turn off the indication LED of the push button.
Delete all learned push buttons of a control group by maintaining pressed the manual control on the blind control module until the output
switches on. Releasing the manual control push button will deactivate the output and turn off the indication LEDs of each corresponding
push button.
Repeat the procedure above to learn other commands to the push buttons.
Exit the learning mode by resetting the address of the blind control module at the original value.
When using firmware version 0735 you will be able to delete all push buttons saved into the memory of the blind control module at once.
Set the address to one of the learning addresses. Maintain the manual control on the blind control module pressed for 10 seconds. The
relay will activate and deactivate again after 7 seconds to confirm the push buttons have been erased. Set the address back to its original
value.