1/2" & 3/4" LARGE PEX CRIMP TOOL
#865894
INSTRUCTION GUIDE
CRIMPS CONFORM TO ASTM F 1807
CONNECTION ASSEMBLY
Cut the tube so that a clean, straight end is provided. Slide the crimp
ring over the tube end. Insert the fitting into the tubing until the
shoulder of the fitting contacts the tubing end. Position the crimp ring
1/8" to 1/4" (3.2 to 6.4 mm) from the cut end of the tubing.
Place the opened jaws of the PEX Crimp Tool around the crimp
ring. Check to be sure that the crimp ring is still properly positioned.
Compress the tool handles to complete the assembly.
CHECK ALL CRIMPS WITH GO/NO-GO GAGE
GAGING PROCEDURE
1.
Determine proper size of tubing: 3/8", 1/2", 3/4" or 1"
2.
If GO cavity fits over crimped ring and NO-GO does not, tool is
crimping properly.
3.
If GO cavity does not fit then handle distance must be increased.
4.
If GO fits—check NO-GO. If NO-GO fits over crimped ring, the
ring is over-crimped, decrease handle distance. Recheck.
NOTE: Over-crimped and under-crimped rings must be removed from
tubing. Crimp with a new copper ring.
ADJUSTMENT PROCEDURE
1.
Close tool handles until pre-load is reached (this is the point at
which jaws touch). Tool should not be completely closed.
2.
Measure the distance between dots on the handle ends as shown.
8 1/4"– 8 3/4" is the correct distance. If the distance is not 8 1/4" –
8 3/4" the tool must be adjusted.
3.
To change the handle ends distance, remove the #6-32 eccentric
lock screw with an Allen wrench and push up eccentric from back.
Rotate eccentric counter-clockwise to increase the handle distance
and clockwise to decrease handle distance. Move eccentric until
hand distance is between 8 1/4" – 8 3/4". Push down eccentric
and re-install the #6-32 lock screw in the appropriate hole which
most closely yields the desired handle distance.
4.
Recheck the set distance after making three crimps. The distance
should be 8 1/4" – 8 3/4" between the "dots" on the handles.
5.
Check the crimps with the go/no-go gauge provided. If satisfactory
crimps do not result, the tool is likely worn and should be replaced.
United States: Oetiker, Inc. | 6317 Euclid Street
Marlette, Michigan 48453 | T +1 800 959 0398
Info.us.marlette@oetiker.com
www.oetiker.com
TOOL MAINTENANCE
1.
Check tool calibration daily.
It is recommended that at
least the first and last crimps
of the day are tested.
2.
Never exceed the specified
handle distance when
adjusting your crimp tool.
Premature wear will result.
3.
Lubricate linkages on a
regular basis to maximize
tool life.
WARRANTY
When properly maintained and
used as intended, the PEX Crimp
Ring Tool is warranted against
materials and manufacturing
defects for a period of 1 year from
date of purchase. This Warranty
does not cover defects or damage
arising from improper installation,
lack of or improper maintenance,
improper storage or handling,
ordinary wear and tear, misuse,
abuse, accident or use of parts
with unauthorized products or
parts. Liability is limited to repair
or replacement of tool or
component parts which are
determined defective as covered
by this Warranty.
DISTRIBUTED BY
RELIANCE WORLDWIDE CORPORATION 2727
Paces Ferry Road SE, Building II, Suite 1800,
Atlanta, GA 30339 | T +1 877 700 4242
Eccentric
Lock
Screw
"DOTS"
8 1/4"– 8 3/4"
HANDLE PRE-LOAD
Gage all crimps as shown.

Publicidad

loading

Resumen de contenidos para SharkBite ̊865894

  • Página 1 1/2" & 3/4" LARGE PEX CRIMP TOOL #865894 INSTRUCTION GUIDE CRIMPS CONFORM TO ASTM F 1807 CONNECTION ASSEMBLY TOOL MAINTENANCE Cut the tube so that a clean, straight end is provided. Slide the crimp Check tool calibration daily. Eccentric ring over the tube end. Insert the fitting into the tubing until the It is recommended that at shoulder of the fitting contacts the tubing end.
  • Página 2 ENGARZADORA PARA PEX GRANDE DE 1/2" Y 3/4" N. ̊ 865894 GUÍA DE INSTRUCCIONES LAS ENGARZADORAS CUMPLEN CON LAS ESPECIFICACIONES DE ASTM F 1807 MONTAJE DE CONEXIONES MANTENIMIENTO DE LA HERRAMIENTA Corte el tubo para que el extremo quede limpio y recto. Deslice el anillo de engarce sobre el extremo del tubo.