Safety Warnings and Shutdowns
AC OUTPUTS
CONDITION
AVAILABLE?
Operating
Yes
normally
Over voltage
No
Low voltage
No
shut down
Electrical
No
over load
Over
No
Temperature
Low voltage
Yes
warning
14
AUDIBLE
LED STATUS
ALARM
200W, 400W
200W
& 750W
none
Green
long pulses
Green -
flashing
1 short, 1
Green -
long
flashing
2 short, 1
Green -
long
flashing
3 short, 1
Green -
long
flashing
short pulses
Green -
flashing
CORRECTION
400W /
750W
Green - On
Red - Off
Green - On
Disconnect the power
Red - On
inverter, check and
repair battery system.
Green - On
Sensitive devices should
Red - On
be shut down. Start ve-
hicle to recharge vehicle
battery or check vehicle
battery voltage.
Green - On
Disconnect
Red - On
appliance(s), disconnect
power inverter, wait a
few minutes, plug in the
power inverter, and plug
in reduced load.
Green - On
Sensitive devices should
Red - On
be shut down. Unplug
accessories and leave
the power inverter
plugged in allowing the
fan to cool the unit.
Clear objects away from
the power inverter to
improve air flow, move
it to a cooler location, or
reduce load if the power
inverter is operating
continuously.
Green - On
Low voltage shutdown
Red - On
is about to occur; sensi-
tive devices should be
shut down. Start vehicle
to recharge vehicle
battery or check vehicle
battery voltage.