Type of error: The keypad shows no results
• The keypad was not pressed correctly Press the keypad on the ON or R
marking. Tapping the keypads is better than pressing.
Type of error: Liquid (water/coolant) in head
• Battery compartment not properly closed Remove battery cover, check
cover O-ring.
• Internal mechanical damage Repair by KOMET
Type of error: Digital display is blank
• The digital display turns off after 30 seconds Press ON on the keypad
• Battery is empty Replace with an original KOMET battery: Order No.
75000 12150. The batteries from other suppliers can create malfunctions of
the electronics.
• Battery is mounted wrong Mount the battery with its positive pole to the
inside (see marking and pictures on page 9)
Type of error: Display shows BA LO
• Wrong battery / battery is empty Use the original KOMET battery Order
No. 75000 12150
Type of error: Display status shows continuous Err2...3...4...5...6
• The boring head was adjusted beyond the maximum adjustment range of
the electronic Adjust the boring head in the opposite direction to about
the center of the total adjustment. The size will show again after about 30
seconds.
Type of error: Display status Err2, Err3, Err4, Err5, Err6, Err7, Err8
• Electronic is defective Repair by KOMET
Type of error: Display status Err4, III E, E III
• Measuring signal within the permissible measuring range (Err4) Electronic
is defective: Repair by KOMET
• The maximal measuring range has been exceeded in plus direction. The
measuring signal is to low (III E) The measuring range in plus direction
exceeded.
• There are circumstances where the measuring signal comes again in a
plausible magnitude (Err4) The measuring range in plus direction far
exceeded
• The maximal measuring range has been exceeded in minus direction. The
measuring signal is to low ( E III) The measuring range in minus direction
exceeded.
• There are circumsstances where the measuring signal comes again in a
plausible magnitude (Err4) The measuring range in minus direction far
exceeded.
Type of error: Display status Err9
• Electronic is defective Remove the battery and mount it again. If the
error remains than send the boring head for repair to KOMET.
EnglIsh