EQUIPMENT AND ACCESSORIES
1.
Glue sticks
- 3 pcs
PREPARATION FOR OPERATION
REMOVING AND INSERTING THE BATTERY
• Press the battery lock button (8) and slide out the battery (9) (fig. A).
• Insert charged battery (9) into the battery installation socket in the handle (6),
you should hear when the battery lock button (8) snaps.
BATTERY CHARGING
The device is supplied with partially charged battery. The battery should
be charged in ambient temperature between 4°C and 40°C. New battery,
or one that has not been used for a long time, will reach full efficiency after
approximately 3 to 5 charge/discharge cycles.
• Remove the battery (9) from the device (fig. A).
• Connect the charger to mains socket (230 V AC).
• Slide the battery (9) into the charger (10) (fig. B). Make sure the battery is
properly fitted (pushed to the end).
When the charger is connected to a mains socket (230 V AC), the green diode
(11) on the charger turns on to indicate connected supply.
When the battery (9) is placed in the charger (10), the red diode (11) on the
charger turns on to indicate that the charging is in progress.
At the same time green diodes (13) of the battery level indication are flashing
in different configurations, see description below.
• All diodes are flashing - battery is empty and requires charging.
• 2 diodes are flashing - the battery is partially discharged.
• 1 diode is flashing - the battery level is high.
Once the battery has been charged, the diode (11) on the charger lights
green, and all battery level diodes (13) light continuously. After some time
(approx. 15 s) the battery level indication diodes (13) turn off.
Do not charge the battery for more than 8 hours. Exceeding this
time limit may cause damage to battery cells. The charger will not turn
off automatically when the battery is full. Green diode on the charger
will remain on. Battery level indication diodes turn off after some time.
Disconnect power supply before removing the battery from the charger
socket. Avoid consecutive short chargings. Do not charge the battery
after short use of the tool. Significant decrease of the period between
chargings indicates the battery is worn out up and should be replaced.
Batteries heat up when charging. Do not operate just after charging –
wait for the battery to cool down to room temperature. It will prevent
battery damage.
BATTERY LEVEL INDICATION
The battery is equipped with the battery level indicator (3 LED diodes) (13).
To check battery level status, press the button for battery level indication (12)
(fig. C). When all diodes are on, the battery level is high. When 2 diodes are on,
the battery is partially discharged. When only one diode is lit, the battery is
discharged and must be recharged.
OPERATION / SETTINGS
The glue gun is designed for use with glue sticks with diameter 11 mm.
Glue dries within 60 seconds. Single operation of applying glue should not
exceed 40 seconds.
Before starting to glue clean surfaces with solvent. Surfaces must be dry with
no trace of oil.
Glue gun trigger is designed only to feed glue stick as it melts. Do not apply
excessive force on the trigger to avoid damaging the feeding mechanism.
• Put a glue stick into the inlet hole (3) and move the switch (5) to ON
position, which is indicated with LED light (4) (fig. D).
• Wait for 3–5 minutes until the glue stick is hot.
• Press on the trigger (7) to feed the glue stick and make the melted glue
flowing out of the nozzle (1) onto material to be joined.
• After finishing glue application, move the switch (5) to the OFF position,
which turns off the LED (4). Then put the glue gun away in vertical position.
• Press both joined surfaces against each other evenly and hold for
approximately 5 minutes.
Do not attempt to remove unused glue from the gun just after the
work is finished. Unused glue left in the glue gun will be heated again at
the next use of the tool.
Do not put the glue gun on its side when it is hot.
When putting the glue gun away, always put it in vertical position. It
ensures that hot gun nozzle or other hot parts have no contact with any
surface in workshop or a table.
When the work is finished, switch off the glue gun and allow it to cool
down before storing.
OPERATION AND MAINTENANCE
Remove the battery from the device before commencing any
activities related to installation, adjustment, repair or maintenance.
MAINTENANCE AND STORAGE
• Cleaning the device after each use is recommended.
• Do not use water or any other liquid for cleaning.
• Clean the power tool with a dry cloth.
• Do not use any cleaning agents or solvents, they may damage plastic parts.
• Always store the power tool beyond reach of children.
• After the glue gun is cooled, store it in a dry place away from sunlight.
• Store the device with the battery removed.
All defects should be repaired by service workshop authorized by the
manufacturer.
TECHNICAL PARAMETERS
RATED PARAMETERS
Cordless Glue Gun 58G040
Parameter
Battery voltage
Glue stick diameter
Temperature of heating tip
Heat up time
Flow rate
Protection class
Weight
Year of production
Graphite Energy+ System Battery
Parameter
Battery
Battery voltage
Battery type
Battery capacity
Ambient temperature range
Charging time for charger 58G002
Weight
Year of production
Graphite Energy+ System Charger
Parameter
Charger type
Supply voltage
Power supply frequency
Charging voltage
Max. charging current
Ambient temperature range
Charging time of the battery 58G001
Charging time of the battery 58G004
Protection class
Weight
Year of production
ENVIRONMENTAL PROTECTION
Electrical equipment must not be disposed off with household waste
and, instead, should be utilized at appropriate facilities. Information
on utilization can be provided by the product vendor or the local
authorities. Waste electrical and electronic equipment contains
substances that are not neutral to the natural environment. Equipment
that is not recycled constitutes a potential hazard to the environment
and to human health.
Storage batteries/batteries must not be disposed with domestic waste,
put in a fire or into the water. Damaged or used up storage batteries
must be properly recycled in compliance with the current directive
pertaining to disposal of storage batteries and batteries.
Li-Ion
8
Value
18 V DC
11 mm
160°C÷210°C
3 min
8 g/min
III
0.4 kg
2020
Value
58G001
58G004
18 V DC
18 V DC
Li-Ion
Li-Ion
2000 mAh
4000 mAh
4
C – 40
C
4
C – 40
C
0
0
0
0
1 h
2 h
0,400 kg
0,650 kg
2020
2020
Value
58G002
230 V AC
50 Hz
22 V DC
2300 mA
4
C – 40
C
0
0
1 h
2 h
II
0,300 kg
2020