OPERATION – INSTALLATION – PARTS MANUAL
WARNING!
DO NOT ATTEMPT TO INSTALL, OPERATE, OR SERVICE THIS PRODUCT BEFORE READING ALL
INSTRUCTIONS CAREFULLY. FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN
INJURY
PROPERTY DAMAGE!
AND/OR
DESCRIPTION
Fostoria multipurpose infrared heaters are designed to
provide efficient spot heating anywhere a 120V, 60 Hz.
bonded receptacle is available.
garages, factories, truck docks, storefronts, terminals, etc.
Not for indoor residential use. Available with two 450
watt individually operated quartz tubes, or one 550 watt
quartz tube. Heaters are equipped with lamp guard, two 4-
ft. suspension chains and an 8-ft. three-wire bonding
(grounding) type cordset.
The housing for model FFH-912B is made from heavy
gauge steel, with a baked-on brown enamel finish. Model
FFH-512A has a gold anodized aluminum reflector and
housing.
Caution: Not recommended for use in potentially
explosive atmospheres (spray areas, chemical
storage areas, etc.) or where excessive moisture
may contact unit (car washes, etc.). For specific
applications,
consult
insurance company.
Read all instructions before using this heater:
WARNING: DO NOT DEPEND UPON A THERMOSTAT OR
OTHER
SWITCH
AS
DISCONNECTING
POWER
SERVICING THE HEATER. ALWAYS UNPLUG THE HEATER.
FAILURE TO DO SO COULD RESULT IN FATAL ELECTRIC
SHOCK.
1.
This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes, and
curtains at least 6 feet (2m) from the front of the heater and
keep them away from the sides and rear.
2.
Extreme caution is necessary when any heater is used by or
near children or invalids, and whenever the heater is left
operating and unattended.
3.
Connect to properly bonded (grounded) outlets only.
4.
Always unplug the heater when not in use. To disconnect
heater, turn controls to off, then remove plug from outlet.
Issue Date: 12-02-97
Rev. Date: 05-05-08
If you have questions about the
product you have purchased or would
like to leave us feedback please
contact us via our website
www.fostoriaindustries.com
or by calling 1-800-495-4525.
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
Use in farm buildings,
local
codes
or
your
IMPORTANT SAFETY INFORMATION
THE
SOLE
MEANS
WHEN
INSTALLING
Rev. Level: 06
ELECTRIC PORTABLE HEATER
REQUIRED CLEARANCE
NOTE: Heaters should be a minimum 3" from ceiling, 24"
from a vertical surface and a minimum 6 ft. from the floor.
SPECIFICATIONS
FFH-512A
Heat source............................One 550W, 120V, 4.6 amp quartz tube
Housing...........................................0.040 gold anodized aluminum
Dimensions............................................22" L x 4 1/2" W x 3 1/4" H
FFH-912B
Heat source...........................Two 450W, 120V, 3.8 amp quartz tubes
Housing................................................Painted galvannealed steel
Dimensions.......................................16 1/2" L x 5 3/4" W x 4 3/4" H
FFH-512A and FFH-912B
Lamp guard......................................0.105 chrome plated steel wire
Suspension...................................................Two, 4ft. jack chains
Power Cord...........................8ft. 18/3 cordset with Nema 5-15P plug
Power Source............................................................120V, 60Hz
5.
Do not operate any heater with a damaged cord or plug or
after the heater malfunctions, has been dropped or damaged
in any manner. Return heater to authorized repair facility for
examination, electrical or mechanical adjustment, or repair.
OF
OR
6.
This heater is not intended for use in bathrooms, laundry
areas and similar indoor locations. Never locate heater where
it may fall into a bathtub or other water container.
7.
Do not run cord under carpeting. Do not cover cord with
throw rugs, runners, or the like.
traffic area and where it will not be tripped over.
8.
Do not insert or allow foreign objects to enter any ventilation
or exhaust opening as this may cause an electric shock or
fire, or damage the heater.
9.
Do not use outdoors.
10. Use this heater only as described in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.
EC0: 1-5888
MODEL & PART NO.'s:
FFH-912B
(08827814)
FFH-512A
(08838900)
FIRE, PERSONAL
5000 hour life expectancy
5000 hour life expectancy
Arrange cord away from
OIPM P/N 8300
Page 1 of 6

Publicidad

loading

Resumen de contenidos para Fostoria FFH-912B

  • Página 1 Housing………….…………………….…..0.040 gold anodized aluminum (grounding) type cordset. Dimensions………………………….…..…..…22” L x 4 1/2” W x 3 1/4” H The housing for model FFH-912B is made from heavy FFH-912B gauge steel, with a baked-on brown enamel finish. Model Heat source….…………...…..Two 450W, 120V, 3.8 amp quartz tubes...
  • Página 2: Important Safety

    Wattage levels in the working area can be increased or lowered by switching ON or OFF some of the heating elements. Model FFH-912B has two heat sources (quartz tubes), and turning off one tube will not affect the direction of heat. Cycling is an alternate of ON/OFF switching and can be accomplished readily with an Input Controller or Percentage Timer.
  • Página 3 REPLACEMENT PARTS LIST and EXPLODED VIEW Top View Figure 4 Model FFH-512A Figure 3 Model FFH-912B REF. Part No. Part No. REF. Part No. Part No. DESCRIPTION QTY. DESCRIPTION QTY. FFH-912B FFH-512A FFH-912B FFH-512A Housing assembly 08050514 08838999 PHD P Screw #8-32 X3/8"...
  • Página 4: Descripción

    Vida de servicio esperada: 5,000 horas. El modelo FFH-912B está fabricado con caja de acero de Dimensiones.. 42 cm Lo. x 15 cm An. x 12 cm Al (161/2"x53/4"x43/4") calibre grueso y esmalte café secado al horno. El modelo...
  • Página 5: Instalación

    #16 AWG (y con un wattage nominal mínimo de 688 watts para el modelo FFH-512A, y de 1,125 watts para el modelo FFH-912B). Además, el cordón de extensión y la clavija deben ser de tres hilos con conexión a tierra.
  • Página 6 LISTA DE PIEZAS DE REPUESTO Y VISTA DESARROLLADA Vista superior Figura 4 Modelo FFH-512A Figura 3 Modelo FFH-912B Pieza No. Pieza No. Pieza No Pieza No REF. DESCRIPCIÓN para para CANT. REF. DESCRIPCIÓN para para CANT. FFH-912B FFH-512A FFH-912B FFH-512A...