Descargar Imprimir esta página

Technical Data; Cam Interface; 9�1 Pin Assignment Cam Interface (12, Fig� 1) - Renfert SILENT compactCAM Manual De Instrucciones

Ocultar thumbs Ver también para SILENT compactCAM:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 72
Trouble
The suction process in
the continuous operation
or automatic operation
stops abruptly and the rel-
evant displays are still on
(20 / 22, Fig. 2).
When the unit is switched on,
not all of the displays light up.
8

Technical Data

Working Voltage:
Permissible mains voltage:
Mains frequency:
Suction turbine power *):

CAM interface:

LpA **) (at max. volume flow):
Input signal:
- Low
- High
Output signal:
- max� pull-up voltage
- max� switching current (I)
- internal series resistor
Filterquality:
Weight (empty), approx�:
Dimensions (width x height x depth):
*) at nominal voltage
**) Sound pressure levels according to EN ISO 11202
9
CAM interface
There is an electrically isolated, bi-directional interface available for communication with the CAM device�
Via two inputs and two outputs, 4 commands can be received from the extraction unit or 4 status informa-
tion can be sent to the CAM machine�
9.1
Pin assignment CAM interface (12, Fig. 1)
Type: RJ45
Pin
1
2
3
4
5
6
7
8
Possible Cause
• The suction turbine is overheated�
• The suction turbine is defect�
• The display which does not light up
is defect�
230 - 240 V
Description
Out2- GND
Out2
Out1- GND
Out1
In2 - GND
In2 - 24 V
In1 - GND
In1 - 24 V
- 13 -
Corrective Action
• Switch the unit off and allow to cool down for at
least 60 min�
• Check whether the suction tube is blocked� Elimi-
nate blockage�
• Switch the unit off and then on again, so that the
filter cleaning process can be carried out. Change
the fine filter (see chap. 6.3) (if the filter cleaning
function does not improve the suction performance)�
• Change the suction turbine�
• Contact Renfert / Service�
2934 2000
2934 2500
230 V
220 V
220 V
50 / 60 Hz
50 / 60 Hz
490 W
460 W
RJ 45 socket
55 dB(A)
0 - 5 V
15 - 24 V
150 Ohm
Class M according to EN60335-2-69
13�2 kg
[29�1 lbs]
245 x 440 x 500 mm
[9�6 x 17�3 x 19�7 inch]
2934 3000
2934 3500
120 V
100 V
120 V
100 V
50 / 60 Hz
50 / 60 Hz
480 W
480 W
24 V
5 mA
EN

Publicidad

loading

Este manual también es adecuado para:

2934 20002934 25002934 30002934 3500