YATO YT-82804 Manual Del Usuario página 15

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 57
GB
Push the battery in the charger socket (II).
Plug the charger into a mains socket.
When the red LED lights up, it means the loading process.
When charging is complete, the red LED goes off , and green LED lights up, indicating a full charge of the battery.
Unplug the charger from the mains outlet.
Remove the battery from the charging station, by pressing the battery latch button.
Attention! The battery should be removed immediately after the charging process is fi nished. Leaving the battery connected to a
working charging station can lead to a fi re hazard.
Attention! If, when the charger is connected to the power supply, the green LED is on, this indicates a fully charged battery. In
this case, the charger does not start charging.
OPERATING OF THE TOOL
ATTENTION! The installation of the equipment may be done only with disconnected power supply. Disconnect the battery from
the tool!
Working with the socket impact wrenches
Before you start screwing the bolt or nut with the wrench, you should by hand screw the bolt or nut on the thread (at least two turns).
Make sure that you correctly choose the size of socket wrench for item, which is tightened or loosened. Bad selection of size may
result in damage of the key or nut or bolt.
Tightening and loosening
Install on the driver the corresponding socket (III).
Select the correct direction of rotation by pressing the switch (IV). The arrow on the switch indicates the direction of linear motion
of nut or bolt during operation.
Connect the battery to the tool.
Grasp the tool with both hands (V).
Push the socket wrench on the nut or bolt head.
Press the switch and hold it. The pressing on the switch allows you to adjust the speed of the key. The greater pressure force on
the switch, the higher the rotational speed of the key.
In the case of tightening, after reaching the maximum torque, the overload clutch engages and the driver drive is disconnected.
You should then release the switch and wait for the complete cessation of engine rotation,
When loosening, make sure that the moment, of what the nut has been tightened, does not exceed the maximum torque of
wrench. In this case the overload clutch also engages and it may not be possible to unscrew the nut.
After unscrewing you should release the pressure on the control switch and wait for the complete cessation of engine rotation.
After fi nishing work, you should disconnect the tool from mains and start maintenance.
Additional notes
Make regular breaks when working.
Do not overload the tool - the outer surface temperature may never exceed 60
C.
o
After the operation switch the tool off , disconnect the battery and make maintenance and inspection.
The total declared value of vibration was measured by standard test methods, and can be used to compare one tool to another.
Declared total value of vibration can be used in a preliminary assessment of exposure.
Attention! Vibration emission during the operation tool may diff er from the declared value, depending on how you use the tool.
Attention! You must specify the security measures to protect the operator that are based on an exposure assessment under
realistic conditions of use (including all part of the work cycle, for example, the time when the tool is switched off or idling and
activation time).
MAINTENANCE AND OVERHAUL
ATTENTION! Before any adjustment, technical service or maintenance operations unplug the tool. Once the operations have been
fi nished, the technical conditions of the tool must be assessed by means of external evaluation and inspection of the following
elements: body and handle, conductor with a plug and defl ection, functioning of the electric switch, patency of ventilation slots,
sparking of brushes, noise level of functioning of bearings and gears, start-up and smoothness of operation. During the guarantee
period, the user cannot dismantle the electric tools or change any sub-assemblies or elements, since it will cancel any guarantee
rights. All irregularities detected at overhaul or during functioning of the tools are a signal to have the tool repaired at a service
shop. Once the functioning has been concluded, the casing, ventilation slots, switches, additional handle and protections must be
cleansed with a stream of air (at a pressure not exceeding 0.3 MPa), with a brush or a cloth without any chemical substances or
cleaning liquids. Tools and handles must be cleansed with a clean cloth.
O R I G I N A L
I N S T R U C T I O N S
15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Yt-82805

Tabla de contenido