Before using your new Battery Charger, please read the following
recommendations
Before to connect the battery, please verify the voltage of it.
Maker sure about power output from the electrical network.
Do not use this charger in humid or wet environments.
Never leave the clamps disconnected, if you still don´t unplug the
charger from the outlet.
Product: Smart charger for sealed batteries
Part number: BR-CHG/BR-500
Brand: Steren
This Steren product is warranted under normal usage against defects in
workmanship and materials to the original purchaser for one year from the date
of purchase.
1.- This warranty card with all the required information, invoice or purchase
ticket, product box or package, and product, must be presented when
warranty service is required.
2.- If the product stills on the warranty time, the company will repair it free of
charge.
3.- The repairing time will not exceed 30 natural days, from the day the claim
was received.
4.- Steren sell parts, components, consumables and accessories to customer, as
well as warranty service, at any of the addresses mentioned later.
THIS WARRANTY IS VOID IN THE NEXT CASES:
If the product has been damaged by an accident, acts of God, mishandling, leaky
batteries, failure to follow enclosed instructions, improper repair by unauthorized
personnel, improper safe keeping, among others.
a) The consumer can also claim the warranty service in the purchase
establishment.
b) If you lose the warranty card, we can reissue it, if you show the invoice or
purchase ticket.
IMPORTANT
WARRANTY
CONDITIONS
INSTRUCTIONS
1. Verify the voltage from the battery (6 or 12V)(12V it´s only available
for BR-500).
2. Select the voltage in the charger, using the voltage switch (located in
the rear).
3.-Use the ends or the clamps to plug the charger to the charger to the
battery (pay attention to polarity).
4. Plug the charger to electrical network.
5. Keep the baterry connected to the electrical current from 6 to 20
hours (depending of the battery), in order to obtain an optimal charge.
(please, refers to the table for more information).
Both models charges every type of lead acid rechargeable
batteries. The part number BR-CHG charges 6V and 12V batteries.
Part number BR-500 includes an charging indicator-LED, when the
battery is charging. the LED lights green, when the battery is
fully-charged lights green.
TIME CHARGING TABLE
BATTERY CAPACITY CHARGE AT CHARGE AT
(AMPERS) 85% 100%
4 3 hrs 6,5 hrs
7 5,5 hrs 11,5 hrs
12 10 hrs 20 hrs
SPECIFICATIONS
BR-CHG BR-500
Input: 120V~ 60Hz 28W Input: 120V~ 60Hz 30W
Output: 6/12 V - - - 1200mA Output: 6/12 V - - - 1400mA
Product design and specifications subject to change without