Descargar Imprimir esta página

Wagner & Co P A2 Top Instrucciones De Montaje

Kit de anclajes

Publicidad

Enlaces rápidos

INSTALLATION INSTRUCTIONS
EN
Roof Bracket Kit P (Top)
P A2 Top / P A2 Hv Top / P Alu Hvn Top / P Stv KF Top / PS Stv Top
INSTRUCCIONES DE MONTAJE
ES
Kit de anclajes P (Top)
P A2 Top / P A2 Hv Top / P Alu Hvn Top / P Stv KF Top / PS Stv Top
ISTRUZIONI DI MONTAGGIO
IT
Kit di fissaggio al tetto P (Top)
P A2 Top / P A2 Hv Top / P Alu Hvn Top / P Stv KF Top / PS Stv Top
Important Notes
EN
DE
The dimensioning of the mounting system (number
of mounting triangels) should be specifically carried
out for each individual project, following the specified
structural engineering standards and regulations (EN
1991 - 3 and - 4).
Prerequisite for the proper application always is a solid
mounting base that can accommodate the occurring
forces (weight, wind and snow loads).
Among others, the regulations of EN 1995-1-1 apply
(Design of Timber Structures.)
Observaciones importantes
ES
Se debe realizar un dimensionamiento del sistema de
montaje conforme a la normativa y orientado al proyec-
to (número de anclajes de tejado etc).
Un subsuelo de fijación adecuado que pueda absorber
la posibles cargas que surjan (peso, carga eólica y por
nieve) es siempre condición de utilización.
Cumplir entre otras la norma UNE-EN 1995-1-1 (Euro-
código 5. Proyecto de estructuras de madera. Parte 1-1:
Reglas generales y reglas para edificación).
Informazioni importanti
IT
Il dimensionamento del sistema di montaggio (numero
delle staffe di ancoraggio, portata delle guide etc) deve
essere eseguito considerando le norme rispettive.
Deve essere garantita un'adeguata sottostruttura per il
montaggio cioè di una sottostuttura in grado di soste-
nere le forze (peso proprio, carico di vento e di neve)
che si verranno a creare.
Osservare inoltre le indicazioni della UNI EN 1995-1-1
(Progettazione delle strutture in legno).
Printed on 100 % recycled paper
Mounting systems XB-INT_Roof-bracket-kit-P-Top_MA-140507-1WA20079
1

Publicidad

loading

Resumen de contenidos para Wagner & Co P A2 Top

  • Página 1 INSTALLATION INSTRUCTIONS Roof Bracket Kit P (Top) P A2 Top / P A2 Hv Top / P Alu Hvn Top / P Stv KF Top / PS Stv Top INSTRUCCIONES DE MONTAJE Kit de anclajes P (Top) P A2 Top / P A2 Hv Top / P Alu Hvn Top / P Stv KF Top / PS Stv Top ISTRUZIONI DI MONTAGGIO Kit di fissaggio al tetto P (Top) P A2 Top / P A2 Hv Top / P Alu Hvn Top / P Stv KF Top / PS Stv Top Important Notes ● The dimensioning of the mounting system (number of mounting triangels) should be specifically carried out for each individual project, following the specified structural engineering standards and regulations (EN 1991 - 3 and - 4).
  • Página 2 P A2 Top MCS012 tested: Wind uplift resistance 513.2 N P A2 Hv Top 86 - 126 145 - 185 MCS012 tested: Wind uplift resistance 538.5 N P Alu Hvn Top 75-105 135-185 39-60 MCS012 tested: Wind uplift resistance 544.5 N...
  • Página 3 PS Stv Top S 15 TX40 TX40 P A2 Hv Top / P Alu Hvn Top S 15 30 Nm XB-INT_Roof-bracket-kit-P-Top_MA-140507-1WA20079...
  • Página 4 S 15 30 Nm Dimensions only for module installation Medidas válidas para la instalación de módulos Dimensioni per l‘installazione dei moduli min 900 mm max 450 mm Subject to modifications, errors excepted · © Wagner & Co, 2014 · www.wagner-solar.com Wagner & Co · Zimmermannstraße 12 · D-35091 Cölbe/Marburg · (06421) 80 07-0 · Fax 80 07-22...