Instructions specific to hazardous area installations
(Reference European ATEX Directive 94/9/EC, Annex II, 1/0/6)
Notes:
• See inside front cover for nameplate illustrations. The nameplate shown is a typical
example. Please check the nameplate on your device for your specific device
configuration.
• Installation shall be performed only by qualified personnel and in accordance with local
governing regulations.
The following instructions apply to equipment covered by certificate number Sira 06 ATEX
9218X.
1.
For use and assembly, refer to the main instructions.
2.
The equipment is certified for use as Category II 1D, 1/2 D & 2D equipment. The Essential
Health and Safety Requirements are assured by compliance with IEC 61241-0: 2004 and
IEC 61241-1: 2004.
3.
The equipment may be used with dust and fibers with apparatus temperature class T
(see table below).
4.
Thermal Data for 7ML5426 Series
Permitted ambient temperature
Device
category
–40 °C (–40 °F) ≤ T
1D, 1/2D, 2D
5.
The equipment has not been assessed as a safety related device (as referred to by
Directive 94/9/EC Annex II, clause 1.5).
6.
Installation and inspection of this equipment shall be carried out by suitably trained
personnel in accordance with the applicable code of practice (EN 61241-14 and EN 61241
–17 in Europe).
7.
Repair of this equipment shall be carried out by suitably trained personnel in accordance
with the applicable code of practice.
8.
Components to be incorporated into or used as replacements in the equipment shall be
fitted by suitably trained personnel in accordance with the manufacturer's
documentation.
9.
It is the user's responsibility to ensure that a manual override is possible in order to shut
down the equipment, and that protective systems are incorporated within automatic
processes which deviate from the intended operating conditions, provided that this does
not compromise safety.
10. Equipment Marking: The equipment marking contains at least the information on the
product label. See product nameplate.
7ML19985QW82
Hazardous area installations
at horn antenna
≤+200°C
amb
(+392 °F)
SITRANS LR460 – QUICK START MANUAL
Permitted ambient
temperature at electronic
enclosure
–40 °C (–40 °F) ≤ T
amb
(+149 °F)
≤ +65°C
Page EN-15