2. Cleaning
Important:
The dispenser should only be cleaned if the through-
put is too small.
After cleaning, a can must be screwed onto the dispen-
ser within one minute.
en
The dispenser must not be cleaned every time a can
is changed.
Preparation
– Screw off the can.
– Make sure that the substrate and the surroundings are
not fouled.
Cleaning
–
– Screw the CFR 1 cleaner onto the adaptor. Thoroug-
hly flush the dispenser until only clear cleaner emer-
ges.
– Leave the cleaner about 30 minutes on the adaptor so
that the foam remaining in the dispenser completly
dissolves. Flush through again.
– The nozzle tip can be cleaned with a knife.
– Don't clean the adaptor using a hard object.
– The dispenser remains under pressure after the clea-
ner can has been removed. The trigger may be ope-
rated only after a foam can has been fitted.
– Screw a can onto the dispenser within 1 minute after
cleaning.
– Immediately pull the trigger for 3 seconds to remove
any remaining cleaner.
Important:
– The dispenser has been designed in such way that
cleaning is seldom or never required if used pro-
perly.
3. Manufacturer's warranty – tools
Hilti warrants that the tool supplied is free of defects
in material and workmanship. This warranty is valid so
long as the tool is operated and handled correctly,
cleaned and serviced properly and in accordance with
the Hilti Operating Instructions, and the technical sys-
tem is maintained. This means that only original Hilti
consumables, components and spare parts may be
used in the tool.
This warranty provides the free-of-charge repair or
replacement of defective parts only over the entire lifes-
pan of the tool. Parts requiring repair or replacement
as a result of normal wear and tear are not covered by
this warranty.
Additional claims are excluded, unless stringent
national rules prohibit such exclusion. In particular,
4
Printed: 07.07.2013 | Doc-Nr: PUB / 5103013 / 000 / 00
– Make sure that there is always a can screwed on the
dispenser.
Always store the dispenser in upright or lying posi-
A
tion with the can screwed on. (Otherwise there is a
risk of the contents curing.)
The can is under pressure.
B
Protect it from the sun and temperatures above +50°C.
Knob to adjust the bead of foam. Turn to the left only
C
until the symbol (recess) appears.
– Don't point the dispenser at anyone.
– Always wear protective gloves and goggles.
– Don't damage the dispenser or can.
– Avoid foam contact with the skin.
– Keep out of the reach of children.
Hilti is not obligated for direct, indirect, incidental
or consequential damages, losses or expenses in
connection with, or by reason of, the use of, or inabil-
ity to use the tool for any purpose. Implied warranties
of merchantability or fitness for a particular purpose
are specifically excluded.
For repair or replacement, send tool or related parts
immediately upon discovery of the defect to the address
of the local Hilti marketing organization provided.
This constitutes Hilti's entire obligation with regard to
warranty and supersedes all prior or contemporane-
ous comments and oral or written agreements con-
cerning warranties.