Cooper Lighting Solutions Fail-Safe B95 LED Instrucciones De Instalación página 3

Publicidad

Idiomas disponibles

Idiomas disponibles

N
ote:
If mounting surface is uneven or rough, it will be
necessary to caulk around fixture to provide water
tight seal between the fixture and the uneven
surface.
6.
Replace the lens. If the lens is painted then the painted
portion must be oriented at top position. Do not
over-torque the screws during the installation of lens.
SHALLOW CAST UNIT INSTALLATION:
1.
Remove lens, using a TORX T20 center pin reject
screwdriver.
2.
Remove back plate using Philips screwdriver (see
Figure 5) and detach quick disconnect.
3.
Remove four knockouts (0.28in diameter) from the rear
face of the casting.
4.
Center cast housing on flat smooth ceiling or wall over
junction box. Use cast housing as a template to layout
fastener locations (see Fig. 6).
5.
Peel the backing from each of the four donut gaskets
and apply them to the back side of the cast housing at
each of the four mounting holes (gasket has adhesive
on one side). Use the square gasket to seal cast
housing to J-Box (see Fig. 7).
6.
Connect fixture wires to the proper supply wires and
place in junction box. Minimum 90 deg. supply wire
required. Ground fixture with wire provided.
7 .
Select the correct type fasteners to use for the
mounting surface, 1/4" nominal diameter (not supplied).
Caution: Do not touch LEDs on fixture; care must be
taken to not come in contact with LED board(s) or
connector(s) during fixture installation.
8.
Align casting without lens & back plate to four mount
holes. Tighten all four mounting fasteners sufficiently to
compress cast housing into gasket.
N
ote:
If mounting surface is uneven or rough, it will be
necessary to caulk around fixture to provide water
tight seal between the fixture and the uneven sur-
face.
9.
Connect the quick disconnect plugs and mount back
plate using four screws.
10. Install lens. If the lens is eyelid type then the painted
portion must be oriented at top position. Do not over-
torque the screws during installation of lens.
Lens
Figure 5.
Mounting Holes
Figure 6.
Donut
Gasket
Figure 7.
COOPER LIGHTING SOLUTIONS IB519088EN
Installation Instructions – B95 LED
Casting With
Back Plate
Casting
Button PC
(Optical)
Installation Instructions
Back Plate
Wall Or
Ceiling
Junction
Box
Square
Gasket