INSTALLATION INSTRUCTIONS
DOWNDRAFT RECIRCULATION KIT
READ AND SAVE THESE INSTRUCTIONS
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer at the address or telephone number in the
warranty.
2. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
3. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
4. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
5. To reduce the risk of fire, use only metal ductwork.
PLAN THE INSTALLATION
IMPORTANT - Installation Requirements
The blower can be installed in either of two ways:
(1) attached to the downdraft and stabilized with
mounting legs.
(2) installed remotely (not attached to the downdraft),
using mounting brackets and wood framing.
Purchase blower separately. (Includes mounting legs and
mounting brackets.)
A minimum 24-inch wide cabinet is recommended.
The 8-inch round blower outlet and 8-inch round
recirculation box inlet must align vertically. (See page 2.)
1. Determine where recirculation box will exhaust through
cabinet.
• Front (toe space), Back, Side (Left or Right).
• 14½" x 15" opening in cabinet base is required for
recirculation box.
• 3½" x 14¼" opening is required for exhaust.
2. Determine location of recirculation box.
• Plan to align blower outlet with recirculation box inlet.
INTENDED FOR DOMESTIC COOKING ONLY
!
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. Clean filters and grease-laden surfaces frequently.
3. Do not repair or replace any part of this appliance unless
specifically recommended in this manual. All other servicing
should be done by a qualified technician.
4. Please read specification label on product for further
information and requirements.
CONTENTS
1 - Recirculation Box
1 - Recirculation Filter
1 - Decorative Grille
1 - Parts Bag (containing):
6 - #10 x .625" screws
4 - #8 x .375" screws
2 - #8 x 1" screws
3. Determine what lengths of duct are required. (Purchase
duct separately.)
• A length of flexible or rigid 8" round duct is required to
connect blower exhaust to recirculation box inlet.
• A length of 3¼" x 14" duct may be required to connect
to exhaust of recirculation box and extend to decorative
grille location.
EXHAUST OPENING
DECORATIVE
GRILLE
1
EXHAUST THROUGH CABINET FRONT (TOE SPACE)
Model ARKD
!
FILTER
RECIRCULATION
OPENING IN
CABINET BASE
14½"
3½" x 14¼"
BOX
15"