5 Initial Operation
5.3
Interface X 7: 24 V E/A
There are two inputs and two outputs availab-
le on this interface, which can be processed
in the tightening program. The relevant func-
tion is assigned with the help of the BS300
operating system under the menu option
"PLC assignment table SE". More detailed in-
formation can be found in the BS300 help
file.
In order to use the inputs with external initia-
tors, the interface's 24 V supply (pins 5, 6)
can be used.
1
2
3
4
5
6
Fig. 4:
Strip terminal, 6pin
Type of plug: e. g. Make Phönix contact, MC
1,5/6-ST-3,5
Pin
Signal Description/
Function
1
IN1
Input 1
2
IN2
Input 2
3
OUT1
Output 1
4
OUT2
Output 2
5
24 V
24 V
for inputs
6
0 V
Reference potenti-
al for outputs
Table 4:
Electric Drives and Controls | Bosch Rexroth AG 13 /40
5.4
The SE302 tightening controller has two
slots, in which the interface modules can be
inserted. There are also interface modules
which can be used for controlling and for
data communication. Available interface mo-
dules:
Module
SMibs
SMpdp
SM24V
SMser
Table 5:
Possible (permissible) assignment
combinations for the slots X8, X9
No module
1 module
Voltage/
Current/
Standard
2 modules
24 V DC
DIN 19 240
24 V DC
DIN 19 240
24 V DC/
100 mA
DIN 19 240
Table 6:
24 V DC/
100 mA
Impermissible assignments: SMeth can-
DIN 19 240
not be used. SMpdp, SMibs can only be
24 V DC/
used once.
300 mA
DIN 19 240
24 V DC/
DIN 19 240
Slots X8, X9: Slots for inter-
face modules
Order number
InterBUS-S
0 608 830 164
Profibus DP
0 608 830 165
24 V E/A
0 608 830 166
RS232, RS422,
0 608 830 167
20 mA
SMser
SMser
X8
SM24V
SMpdp
SMibs
SMser
SM24V
SM24V
SM24V
SM24V
SMpdp
SMibs
SMser
SM24V
SM24V
X9
SM24V
SMpdp
SMibs
SMser
SM24V
SMpdp
SMibs
SMser
SM24V
SM24V
SM24V