INSTRUCTIONS FOR USE
ISTRUZIONI PER L'USO
cartridge and contact your dealer
OPERATlNG THE TORCH
2.1 Always point the nozzle away from your body and any flammable or combustible objects.
2.2 Turn the OPEN/CLOSE Contral knob counterclockwise approx 1/2 turn to open the gas valve,
press the satety Latch and Trlgger together to ignite the torch.
2.3 For continuous flame, slide the Hands-free Lock to HOLD position.Then release the Safety Latch
and Trlgger.
2.4 To extinguish the flame,slide the Hand-frees Lock to OFF position and turn the ControlKnob
clockwise to CLOSE to turn off the gas.
2.5 Always use Safety Stand & Wire Stand for better stability and multiple angles use during operation.(fig.3)
2.6 After use,ensure that the Control Knob is fully shut (turned fully clockwise).Take the torch /gas
cartridge assembly outdoors and unscrew torch from the gas cartridge.
HOW TO CHANGE NOZZLE
3.1 Be sure the nozzle is cool before removal.
3.2 Unscrew the Knurled Nut in counterclockwise direction to remove the nozzle. lnstall the
desired nozzle into the body. Align the Nozzle Protrusion area with arrow pointed direction to the
body (Fig.4) and carefully push the nozzle into the body (Fig. 5). Gently screw the Knurled Nut on
the threads. Be careful not to overtighten as it could damage the nozzle assembly and threads in
the body.
interchangeable nozzle
1
open/close control knob
2
off/hold, hands-free lock
3
gas cartridge
4
torch
6
wire stand
7
trigger
8
knurled nut
9
safety latch
10
pin point flame nozzle
11
swirl flame nozzle
12
arrow on the body
14
nozzle protrusion with arrow
15
6
EN
I