Base Grille Water Filtration System
Model WF-L200V capacity 200 gallons (757 liters)
Model WF-NL120V capacity 120 gallons (454 liters)
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than
or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42/53.
Substance
NSF Reduction
Reduction
Requirements
Aesthetic Effects
Chlorine Taste/
≥ 50 %
Odor Particulate
≥ 85 %
Class III*
Contaminant
NSF Reduction
Reduction
Requirements
Lead: @ pH 6.5
0.01 mg/L
Lead: @ pH 8.5
0.01 mg/L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Benzene
0.0050 mg/L
p-dichlorobenzene
0.075 mg/L
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 63 °F (17.2 °C).
APPLICATION GUIDELINES/WATER SUPPLY
PARAMETERS
It is essential that operational, maintenance, and fi lter
replacement requirements be carried out for the
product to perform as advertised.
Model WF-L200V: The fi lter monitor system measures
the amount of water that passes through the fi lter and
alerts you to replace the fi lter. When 90 % of the fi lter's
rated life is used, the fi lter indicator light changes from
green to yellow.
When 100 % of the fi lter's rated life is used, the fi lter
indicator light changes from yellow to red, and it
is recommended that you replace the fi lter. Use
replacement cartridge L200V / NL120V, part #4396702.
2014 suggested retail price of $32.99 U.S.A./ $49.99
Canada. Prices are subject to change without notice.
Model WF-NL120V: Change the water fi lter cartridge
every 6-9 months. Use replacement cartridge L200V
/ NL120V, part #4396702. 2014 suggested retail price
of $32.99 U.S.A./ $49.99 Canada. Prices are subject to
change without notice.
Class III particle size: >5 to <15 um
**Test requirement is at least 10,000 particles/mL of AC Fine Test Dust.
***These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
®NSF is a registered trademark of NSF International.
PRODUCT DATA SHEETS
Influent
Average
Challenge
Influent
Concentration
2.0 mg/L ± 10 %
1.9 mg/L
At least 10,000
49,333/mL
particles/mL
Influent
Average
Challenge
Influent
Concentration
0.14 mg/L***
0.15 mg/L ± 10 %
0.15 mg/L***
0.15 mg/L ± 10 %
0.0059 mg/L
0.006 mg/L ± 10 %
0.0054 mg/L
0.006 mg/L ± 10 %
0.0157 mg/L
0.015 ± 10 %
0.210 mg/L
0.225 ± 10 %
Tested and certified by NSF International
against ANSI/NSF Standard 42 for the reduction
of Chlorine, Taste and Odor, Particulate Class
lll*; and against ANSI/NSF Standard 53 for the
reduction of Lead, Mercury, Benzene, and
p-dichlorobenzene.
Maximum
Average
Effluent
Effluent
0.07 mg/L
0.06 mg/L
640 mg/L**
312 mg/L
Maximum
Average
Effluent
Effluent
0.0014 mg/L
0.0011 mg/L
0.0069 mg/L
0.0042 mg/L
0.0009 mg/L
0.0004 mg/L
0.0007 mg/L
0.00043 mg/L
0.002 mg/L
0.00083 mg/L
0.0005 mg/L
0.0005 mg/L
The product is for cold water use only.
Do not use with water that is microbiologically unsafe
or of unknown quality without adequate disinfection
before or after the system.
Refer to the front cover or "Accessories" section for the
Manufacturer's name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's
limited warranty.
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature 33 °F - 100 °F (0.6 °C - 37.8 °C)
Service Flow Rate
0.5 GPM (1.89 L/min.) @ 60 psi. (413.7 kPa)
Minimum %
Average %
Reduction
Reduction
>75.0 %
>75.0 %
98.7 %
99 %
Minimum %
Average %
Reduction
Reduction
99.0 %
99.21 %
95.4 %
97.08 %
84.74 %
92.47 %
87.03 %
91.93 %
87.26 %
87.26 %
99.76 %
99.76 %
21