IMPORTANT SAFETY INFORMATION
CAUTION! The individual user should determine prior to use whether this device is
suitable, adequate or safe for the use intended. Since individual applications are
subject to great variation, the manufacturer makes no representation or warranty
as to the fit or suitability of these devices for any specific application.
CAUTION! Ensure that the power supply matches the voltage rating of the light.
PERMANENT MOUNT MODELS
MVLP Installation
1. Using holes in the bottom of the plastic housing as a template, mark and drill holes on the
intended surface for suitable fasteners.
2. Connect the RED conductor to a user supplied switch connected to a POSITIVE battery terminal.
Securely connect the BLACK conductor to the NEGATIVE battery terminal (or vehicle chassis,
if grounded).
3. Check for proper operation before use.
MV2 Installation
1. Select a suitable installation location. The warning light must be mounted on a surface no more
than ½" thick for the base to sit flush with mounting surface. When installing, be sure that the
power is off.
2. Drill a 1/4" diameter hole for the threaded rod attached to the center of the base.
3. WIRING THROUGH HOUSING: Drill a 7/16" hole in the mounting surface within the footprint of
the base and install the rubber grommet. Feed power wire(s) through the grommet to protect them.
WIRING THROUGH PERIMETER OF BASE: Remove the plastic plug and replace it with the
provided grommet. Use the same method to feed the power wires through the mounting surface.
4. 12 VDC Models: Slip the 1/4" ring terminal of the black wire over the mounting screw protruding
from the rubber shock mount as a contact to the vehicle ground. In order to ensure that light is
grounded, scrape any paint from the mounting surface to expose bare metal.
24, 36, and 48 VDC Models: Connect the RED conductor to a user supplied switch connected
to a POSITIVE battery terminal. Securely connect the BLACK conductor to the NEGATIVE
battery terminal (or vehicle chassis, if grounded).
5. Choose enough 1/4" flat washers from the shock mount assembly to compress the rubber gasket
to the mounting surface to prevent water leakage. Solidly secure the mounting screw with the
nut provided.
6. Check for proper visibility and operation of the light.
info@triliteinc.com | t: 1-773-384-7765 | f: 1-773-384-5115 | www.triliteinc.com | Designers and manufacturers of specialty electrical products. Since 1922.
INSTALLATION INSTRUCTIONS for MODELS
MVLP and MV2 DC ROTATING LIGHTS
MV2
MVLP
950096 | REV B