Gardena 20000DIRT Instrucciones De Empleo página 13

Ocultar thumbs Ver también para 20000DIRT:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 59
Pump
Small hose diameter
Art. GARDENA Hose Clamp
Medium hose diameter
Art. GARDENA Hose Clamp
Large hose diameter
Art. GARDENA Hose Clamp
When using the 38 mm (1 1/2") hose, we recommend the
GARDENA Flat Hose Set Art. 5005 with 10 m hose and
hose clamp.
To connect the hose via the connection nipple:
1. When using the large diameter hose, cut off the
(4)
connection nipple
2. When using the medium hose diameter, cut off the
(4)
connection nipple
3. Push the hose onto the connection nipple
3. OPERATION
DANGER! Risk of injury!
Injury when the product starts accidentally.
v Disconnect the product from the mains before
you connect, adjust or transport the product.
To pump water:
If the pump cannot be immersed via the handle, the
pump must always be immersed via a rope. Attach
the rope by pulling it through the eyelets provided and
knotting it. Minimum immersion depth during initial
operation see 7. TECHNICAL DATA.
Take care that the pump is located where the inlet open-
ings at the suction base are not obstructed neither com-
pletely nor partly.
Stand the pump on a brick if using in a pond.
If the suction process is close to the minimum water level
at start-up, the suction process may take longer.
1. Immerse the pump.
2. Connect the pump to the mains.
Attention! The pump can start immediately depending
on the float switch setting.
Automatic mode with float switch [ Fig. O1 ]:
By adjusting the float switch
sibility to determine the switching heights. For safe
operation, the float switch must be able to move
freely around the pump.
To adjust the Cut-in and Cut-out Height [ Fig. O1 ]:
The maximum cut-in height and minimum cut-out height
(see 7. TECHNICAL DATA) can be adjusted by pushing the
float switch wire into the float switch lock.
9045-20.960.01.indb 13
Art. 9045
32 mm (1 1/4")
Art. 7194
38 mm (1 1/2")
Art. 7195
51 mm (2")
Art. 7196
(a)
at
.
(b)
at
.
(4)
.
(5)
you have the pos-
4. Fix the hose to the connection nipple
a GARDENA Hose Clamp.
To assemble the pump connection [ Fig. A5 ]:
DANGER! Risk of injury!
Cut injury by the impeller.
v Operate the pump only with the elbow
connector.
The hose can be easily connected and disconnected using
(2)
the locking devices
on the elbow connector
1. Screw the elbow connector
until it stops. (If the hose is to be installed horizontally,
(1)
the elbow connector
can be screwed out again up
to half a turn.)
2. Screw the connection piece
ple
(4)
.
3. Push the connection nipple
(1)
elbow connector
until it stops and it engages audibly
and visibly.
The hose is securely connected to the pump.
• The higher the cable is clamped, the higher the cut-in
and cut-out height.
• The shorter the length of cable between the float
(5)
switch
and the float switch lock
cut-in height and the higher the cut-out height.
1. Push the cable of the float switch
openings of the float switch lock
2. Check that the pump switches off automatically.
CAUTION!
v In order to ensure that the float switch is able to
switch on and off, the cable length between the
float switch and the float switch lock must be at
least 10 cm.
Manual operation [ Fig. O2 ]:
The pump remains permanently in operation because
the float switch is bypassed.
1. Slide the float switch
(5)
with the cable downwards onto
the float switch locking device
2. Place the pump on a firm surface.
3. Connect the pump to the mains.
Attention! The pump begins operating immediately.
The pump runs permanently without dry-running protection
due to the bypassed float switch. To avoid damage due to
dry running, only operate under supervision.
The minimum residual water depth (see 7. TECHNICAL
DATA) is only achieved in manual mode because the float
switch already switches off the pump before this when in
automatic mode.
(4)
e. g. with
(1)
.
(1)
clockwise into the pump
(3)
into the connection nip-
(4)
of the hose into the
(A)
, the lower the
(11)
into one of the
(A)
.
(A)
.
13
02.11.20 15:52

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

9045

Tabla de contenido