1. Introduction
Thank you for buying this DCA150! Read this manual carefully before bringing the device into service.
2. Specifications & Functions
Measuring range
0-200mm / 0-8"
200-300mm / 8-12"
300-500mm / 12-20"
Maximum measuring speed:
Display:
Battery:
Operating temperature:
Storage temperature:
Operating humidity:
1. OFF/ON key
2. Zero setting (resets any value to zero for reference)
3. Battery cover
4. METRIC / INCH change over (true conversion)
5. LCD display, features minus sign "-", character in 4.7mm / 0.185" height
for 5 digits, "mm" indication for millimetres and small digit "5" and "IN"
indication for inch measuring unit.
3. Maintenance Instructions
1. Keep the device clean and prevent liquids from entering the electronic part to avoid damaged electronics.
2. Clean the device with petrol, lubricate the body with some clock oil. Acetone and alcohol should not be used.
4. Troubleshooting
Problem
The 5 digits change every second
Displayed value doesn't change.
LCD shows 000.00mm / 00.000in
Function keys do not work
Calliper does not measure
accurately
No display on LCD screen
5. Applications (see p. 6)
DCA150
DCA150 – DIGITAL CALLIPER
Resolution & Repeatability
0.01mm / 0.0005"
1.5m/sec or 60"/sec
LCD
one 1.5V silver oxide battery for one year of continuous use.
Low-battery warning by flashing display.
0°C ∼ +40°C
-20°C ∼ +70°C
0 to 80%
Cause
Battery voltage is under 1.45V
Circuitry malfunction
One of the keys is short circuited
Key spring is bent or deformed
Sensor is dirty
1) No battery contact.
2) Battery voltage is under 1.1V.
Replace battery.
Remove the battery and put it back after 30 seconds.
Remove the cover & adjust key spring position
Remove the cover & adjust key spring position
Remove the cover and slider assembly, clean the
sensor with pressure air (≤51kg/cm²), and clean it
with a little petrol for dirt prevention.
1) Restore battery contact.
2) Replace battery
1
Accuracy
0.03mm / 0.001"
0.04mm / 0.0015"
0.05mm / 0.002"
Solution
VELLEMAN

Publicidad

loading

Resumen de contenidos para Velleman DCA150

  • Página 1 DCA150 – DIGITAL CALLIPER 1. Introduction Thank you for buying this DCA150! Read this manual carefully before bringing the device into service. 2. Specifications & Functions Measuring range Resolution & Repeatability Accuracy 0-200mm / 0-8" 0.03mm / 0.001" 0.01mm / 0.0005"...
  • Página 2: Problemen & Oplossingen

    DCA150 – DIGITALE SCHUIFMAAT 1. Inleiding Dank u voor uw aankoop! Lees deze handleiding aandachtig door voor u uw DCA150 in gebruik neemt. 2. Specificaties & Functies Meetbereik Resolutie & Herhaalbaarheid Nauwkeurigheid 0-200mm / 0-8" 0.03mm / 0.001" 0.01mm / 0.0005"...
  • Página 3: Problèmes/Solutions

    DCA150 – PIED À COULISSE NUMÉRIQUE 1. Introduction Nous vous remercions de votre achat ! Lisez attentivement ce manuel avant de mettre ce DCA150 en service. 2. Spécifications & fonctions Champ de Mesure Résolution / Répétabilité Précision 0-200mm / 0-8"...
  • Página 4: Introducción

    DCA150 – PIE DE REY DIGITAL 1. Introducción ¡Gracias por haber comprado el DCA150! Lea cuidadosamente las instrucciones del manual antes de usarlo. 2. Especificaciones & Funciones Rango de medida Resolución / Repetibilidad Precisión 0-200mm / 0-8" 0.03mm / 0.001"...
  • Página 5 DCA150 – DIGITALE SCHIEBLEHRE 1. Einführung Wir bedanken uns für den Kauf der DCA150 ! Lesen Sie diese Bedienungsanleitung vor Inbetriebnahme sorgfältig durch. 2. Technische Daten & Funktionen Messbereich Auflösung & Wiederholbarkeit Genauigkeit 0-200mm / 0-8" 0.03mm / 0.001" 0.01mm / 0.0005"...
  • Página 6 5. Meten waar het scherm de andere kant opstaat (met nulknop) 5. Mesurer ou l'écran face l'autre côté (avec bouton zéro) 5. Medir donde la pantalla esté enfrente del otro lado (con botón "0" ) 5. Messen wo das Display der anderen Seite gegenüberliegt (mit Nullstellung) DCA150 VELLEMAN...