Only qualified personnel should attempt to
work on this equipment. There are no user
serviceable parts inside of the machine.
Your machine has been designed for years of trouble free operation. The
following is a troubleshooting guide to help you through some of the
problems that may be encountered.
Symptom
Machine does not cycle
Die does not go into machine
!
NOTICE
have been tested with a duty cycle of 25 cycles per minute with a 1
minute rest period after 2 minutes of run time. Operating outside of these
limits could result in machine damage.
The HD7000,
HD7100
E179574.

Troubleshooting

Possible Cause
1) Machine is off
2) Machine is not plugged in
3) Foot-pedal is not plugged into
machine
4) Die lock handle is not locked
5) Reversing tool is in machine
1) Pin retainer interference
2) Punch is stopped in mid cycle
3) Die lock handle is in lock position
The HD7700/H, HD7650, HD7100, HD7000,
HD7000 Plus,
HD6500,
and HD6500 have earned the UL Listing Mark.
13
Action
1) Check power switch
2) Check both ends of power cord
3) Make sure foot-pedal cable is
attached to machine.
4) Lock the die lock handle
5) Remove reversing tool and
store properly
1) Make sure pin retainer enters slot
in pusher-bar.
2) Restart machine by turning power
off and back on
3) Move handle to unlock position