Installation Instructions – Galleon / Galleonaire
Installation Instructions
Tools Required
Ratchet, a shallow 3/4" socket and #2 Phillips head
screwdriver.
Pole Mount
1.
Loosen (3) screws located in the access door of the
fixture and open the door.
2.
Install the 1st threaded rod through the top side hole at
the back of the fixture. Slide a lock washer and nut onto
the rod inside the housing but do not tighten. No more
than 1/2" of bolt should pass through the nut inside the
housing in order to be able to tighten the nut during
step 8.
3.
Install the 2nd threaded rod through the bottom side
hole at the back of the fixture. Slide a lock washer and
nut onto the rod inside the housing but do not tighten.
No more than 1/2" of bolt should pass through the
housing in order to be able to tighten the nut during
step 8.
4.
Remove the pole top cap.
5.
Insert the threaded rods from steps 2 and 3 through
the upper and lower holes of the arm. Make sure the
angled edge of the arm matches the angle at the back
of the fixture so that the assembly will be level upon
completion. The long side of the arm should be at the
top of the fixture.
6.
Route the fixture leads through the center opening of
the arm and through the center opening of the pole.
7 .
Hold the nut plate on the inside of the pole and insert
the mounting bolts through the pole and thread into the
nut plate. Assure that the bolt is completely threaded
through the nut plate.
8.
Tighten both nuts within the fixture to 40 ft-lbs./
54 N·m. A shallow 3/4" socket must be used in order
to guarantee clearance of all drivers inside the fixture
during this step.
9.
Attach the supply side ground wire to the ground
terminal connector (green wires).
10. Connect the supply side line voltage wire to the fixture
side line voltage terminal connector (black wires).
11. Connect the supply side neutral wire to the fixture side
neutral wire terminal connector (white wires).
12. Close the cover and tighten the three screws to insure
the fixture will maintain it's water tight seal.
13. Replace pole top cap after completion of fixture
installation and wiring.
2
COOPER LIGHTING SOLUTIONS
IB500021EN
Installation instructions
N
otee:
For installation to round poles follow the same
instructions as the square pole installation with the
additional round pole adaptor inserted between the
pole and the arm. (Figure 1.)
Grommet (For Service Leads)
Threaded Rod
Angled Edge
Arm
Nut Plate
Access Door
Round Pole Adapter (Optional)
Figure 1.
Tools Required
#2 Phillips screw driver, ratchet and a 3/4˝ shallow socket.
Wall Mount
1.
Loosen (3) screws located in the access door of the
fixture and open the door.
2.
Install the 1st mounting bolt through the top side hole
at the back of the fixture. Slide a lock washer and nut
onto the bolt inside the housing but do not tighten.
3.
Install the 2nd mounting bolt through the bottom side
hole at the back of the fixture. Slide a lock washer and
nut onto the bolt inside the housing but do not tighten.
4.
Slide the included arm over the bolts as shown in
Figure 2. Make sure the angled portion of the arm
matches the angle at the back of the fixture so that the
assembly will be level upon completion. The long side
should be at the top of the fixture.
5.
Place the decorative wall plate over the arm bolts and
secure to the back side of the arm using the supplied
lockwasher and nuts.
6.
Tighten the nuts on the back of the decorative wall
plate to 40 ft-lbs./54 N·m. Set the fixture assembly
aside.
Mounting Hardware Detail