OPERATING ISSUE
Channel-specific error (Ex: E41 –
Channel 1 overload) – Everything
except PIEZO errors (E59-E63).
Desk is uneven.
PAGE 9 OF 39
TROUBLESHOOTING CONTINUED
1. Swap the motor cable connections at the control box. If It
remains E41, there could be a problem with the workbench or a
bad control box. If the error changes to E42, go to step 2.
2. Swap the motor cable connections at the desk legs, so the leg
that was originally connected to Channel 1 is back in Channel
1, but with the motor cable that was originally connected to
Channel 2. If it remains E42, it is most likely a bad motor cable. If
it goes back to E41, it is most likely a bad leg.
1. Initialize the control box, see page 8. If both legs begin to run down,
complete the initialization. If only one leg moves, stop and move to
Step 2.
2. Check motor cable connections. Check to ensure motor cables
are not pulled during movement. With a standard, Plug & Play
control box, it is possible that only one leg is connected, and
connected to Channel 1. In this case, it will initialize and run
Channel 1 only. If there is only one leg but it is connected to
Channel 2, it will not initialize.
3. If a motor cable was disconnected, try initializing again. If
unsuccessful, connect the desk leg from Channel 2 into Channel
1, with nothing in Channel 2, and initialize.
4. Try initializing the same leg in Channel 1, but with a different
motor cable. If it still won't initialize, contact Uline Customer
Service at 1-800-295-5510.