ACTIVATE USER CODES
1.
Enter: # - Master Code or Manager Code - #
2. The set light will stay orange for ten seconds.
3. Enter User ID Number (3-7) - * - New User Code
- # - New User Code - #, before the orange light
disappears.
NOTE: If a mistake is made during the change,
wait 30 seconds to repeat steps 1 through 3.
NOTE: The lock will indicate a valid code
change with a single signal.
NOTE: The lock will indicate an invalid code
change with a double signal and the old code
is still valid.
CHANGING THE USER CODE
1.
Enter: # - User Code - #
2. The set light will stay orange for ten seconds.
3. Enter: New User Code - # - New User Code - #,
before the orange light disappears.
NOTE: If a mistake is made during the change,
wait 30 seconds to repeat steps 1 through 3.
4. Test new code several times before closing the door:
Enter: * - User Code - #
NOTE: The lock will indicate a valid code
change with a single signal.
NOTE: The lock will indicate an invalid code
change with a double signal and the old code
is still valid.
NOTE: The Master and Manager can also
change the user codes by following the
"Activate User Codes" section steps 1 through 3.
DELETING USER CODES
1.
Enter: # - Master Code or Manager Code - #
2. The set light will stay orange for ten seconds.
3. Enter: User ID Number (3-7) - * - # - #
DUAL USER MODE
NOTE: For additional security, set safe to dual
user mode. This feature requires one user to
enter a code, and within 60 seconds, a second
user must enter a code to unlock the safe.
PAGE 2 OF 9
USAGE CONTINUED
ANY CODE + ANY CODE TO UNLOCK
1.
Enter: # - Master Code - # - 1 - # - 1 - #
2. The lock will indicate a valid setting change with a
single signal.
MASTER OR MANAGER CODE + USER CODE
TO UNLOCK
1.
Enter: # - Master Code - # - 2 - # - 2 - #
2. The lock will indicate a valid setting change with a
single signal.
OPENING SAFE IN DUAL USER MODE
1.
Enter: # - 1st Code - # - 2nd Code - #
2. The lock will indicate a valid code entry with a single
signal and the open light will stay green for five
seconds.
3. Turn the handle clockwise before the green light
disappears.
RETURNING TO SINGLE USER MODE
(SINGLE CODE TO UNLOCK)
1.
Enter: # - Master Code - # - 0 - # - 0 - #
2. The lock will indicate a valid setting change with a
single signal.
TIME DELAY MODE
ACTIVATE TIME DELAY
1.
Enter: # - Master Code - # - (01-99) - # - (01-99) - #
2. The lock will indicate a valid setting change with a
single signal.
•
3. Press * or # to initiate the Time Delay.
Example: # - Master Code - # 05 - # - 05 - #,
this will set a five minute time delay.
NOTE: During the time delay the keypad will
not respond to any entries.
NOTE: The lock will flash once every five
seconds during time delay and will flash once
every second during the last ten seconds of the
time delay ending with a double signal. It will
flash twice every five seconds during the two
minute open period.
NOTE: During the open period the safe can be
unlocked or programmed.
0521 IH-7767