Introduction
Congratulations on your purchase of the Extech Model
CB10 Circuit Breaker Finder and Receptacle Tester. This
instrument is shipped fully tested and calibrated and, with
proper use, will provide years of reliable service.
Meter Description
Receiver
1.
Indicating L ED and Bee
2.
ON/OFF and Sensitivity
3.
Transmitter storage
Note that battery compartment is located on
rear of receiver
Transmitter
4.
Receptacle LED coding scheme
5.
GFCI test button
6.
Receptacle LED's
Gf(]Tesler
Tra/lSMltltlforCB10
I
4
5
This symbol adjacent to another symbol,
terminal or operating device indicates that
the operator must refer to an explanation in
the Operatingilnstructions to avoid personal
injury or dam 9 ge to the meter.
NG
This WARNI
symbol indicates a
potentially ham.rdous situation, which if not
result in death or serious
avoided, coul
injury.
symbol indicates a
This
potentially ha
avoided, ma
This symbol
protected
ghout by double insulation or
reinforced ins
Operating Voltage
90 to 120V
Operating Frequency
47 to 63Hz
Power supply
9V battery (receiver)
Operating Temperature
41 QF to 104QF (5QC to 402C)
Storage Temperature
_4°F to 140°F (-20°C to 60°C)
Operating Humidity
Max 80% up to 87QF (31QC)
decreasing linearly to 50% at
104QF (402C)
Storage Humidity
<80%
Operating Altitude
7000ft. (2000meters) maximum.
Weight
5.90z (167g)
Dimensions
8.5" x 2.2" x 1.5" (215 x 56 x
38mm)
Approvals
UL CE
UL Listed
The UL mark does not indicate that
this product has been evaluated
for the accuracy of its readings.
EXTECH INSTRUMENTS CORPORA TlON
instrument to be free of defects in parts and workmanship for
one year
from date of shipment (a six month limited warranty
applies to sensors and cables). If it should become necessary
to return the instrument for service duri n g or beyond the
warranty period, contact the Customer Service Department at
(781) 890-7440
210
ext.
for authori z ation or visit our website
www.extech.com
for
contact
information.
Authorization (RA) number must be issued before any product
is returned to Extech. The sender is responsible for shipping
charges, freight, insurance and proper packaging to prevent
damage in transit. This warranty does not apply to defects
resulting from action of the user such as misuse, improper
wiring,
operation
outside
of
specification,
maintenance or repair, or unauthori z ed modification. Extech
specifically disclaims any implied warranties or merchantability
or fitness for a specific purpose and will not be liable for any
direct, indirect, incidental or consequential damages. Extech's
total liabifity is limited to repair or replacement of the product.
The warranty set forth above is inclusive and no other
warranty, whether written or oral, is expressed or implied.
warrants
this
A
Return
improper

Publicidad

loading

Resumen de contenidos para Extech Instruments CB10

  • Página 1 Introduction avoided, ma Congratulations on your purchase of the Extech Model This symbol CB10 Circuit Breaker Finder and Receptacle Tester. This protected ghout by double insulation or instrument is shipped fully tested and calibrated and, with reinforced ins...
  • Página 2 Plug the Transmitter / Receptacle tester into the outlet. The three LED's will indicate circuit condition. The B� diagram lists all of the conditions that the CB10 can detect. The LED's in this diagram repr&sent the view Support line (781) 890-7440 from the GFCI button side of the transmitter.
  • Página 3 LED du recipient precision de ses mesures. Sensitivity AdjUst Garantie EXTECH INSTRUMENTS CORPORA TION garantil que eel instrument est exempt de defeefuosile ou de detaul de fabri c ation pendanl une periode d'un an a compler de la date de li v raison (une garanlie limitee de six mois S'iI est applicable pour les sondes et les cables).
  • Página 4 Branchez l'Emetteurrresteur de Recipient sur la prise d'alimentation, Les trois LED indiqueront I'etat du circuit. Le diagramme affichera tous les etats que Ie CB10 peut detecter. Les Assistance telephonique (781) 890-7440 LED sur ce diagramme representent la visualisation du Assistance 200;...
  • Página 5 50% a Observe que el compartimiento de la baterfa ° C (104°F) esta atras del receptor Humedad almacenamiento <80% Extech CB10 Altitud de opera cion 7000ft. (2000 metros) maxima. Peso 167g (5.90z) Dimensiones 215 x 56 x 38mm (8.5" x 2.2" x 1 .5")
  • Página 6 Internet: www.extech.com Extech Instruments Corporation, 285 Bear Hill Road, Waltham, 02451 Prueba de enchufe leFT � s de usar el probador, presione el boton TEST en el enchufe ICFT instalado, el ICFT debe dispararse.
  • Página 7 Adjustable sensitivity for pinpointing the correct breaker User's manual located between cardboard packaging.
  • Página 8 Humidity Meters • 93950 40010 FIber Optic Meters Water Quality Meters • Extech Instruments Corporation nZP4 extech.com 11 1 111111111111 1 1 1111 1 1 1 1 1 1 1 1 1 1 Copyr/gllt 2011 7 ·21108 ExI«h Inslrumenls CotporaUoo.