ELECTRIC SHOCK HAZARD
The unit must be electrically grounded. Use only on
GFCI protected receptacles.
Connect to a properly grounded outlet only. Do not cut
off the grounding prong. Do not use with an adapter.
Do not use with extension cords.
Do not use with damaged cord or plug. If unit is not working as
it should, has been dropped, damaged, left outdoors, or
exposed to water, return it to an authorized service center for
repair.
Unplug cord from outlet when not in use or when servicing unit.
ELECTRIC SHOCK HAZARD
Keep motor and electrical parts dry.
Do not use outdoors. For indoor use only.
Do not handle plug or unit with wet hands.
Do not operate unit in standing water.
BREATHING HAZARD
When using the HEPA 700 in a containment area, turn
off all sources of power to open combustion
appliances such as fireplaces, boilers, furnaces, water
heaters and HVAC systems to avoid the risk of backdrafting
deadly carbon monoxide fumes.
WARNING: This product may expose you to
chemicals, including lead and phthalates, known to the
State of California to cause cancer, birth defects, or
other reproductive harm. For more information, go to
P65Warnings.ca.gov
Parts Identification
Filter cover buckle
(×4). Release to
replace filter
elements.
Air intake
ring. Attach
14 in. semi-
rigid ducting.
Inlet and
inlet cover.
Remove
cover before
operating.
125385C HEPA 700
Quick Start Guide
HEPA 700 Air Scrubber
Control panel.
SPECIAL FEATURES
Command Hub Technology
Integrated Command Hub technology with the free Command
Center mobile app enables firmware updates and 24/7
monitoring and control to ensure optimal air filtration. (App
available soon in Apple and Google Play stores.)
Ducting options
The inlet can accommodate standard 14 in. wire reinforced
ducting (purchased separately).
The outlet can accommodate standard 14 in. layflat or wire
reinforced ducting (purchased separately) using the provided
duct attachment ring. Take care not to bend or otherwise
damage the attachment ring when installing the ducting. Do not
exceed a maximum ducting length of 25 ft. / 7.6 m.
Negative Pressure Setup
The HEPA 700 can be set up for a negative pressure
containment area. Only professionals with the appropriate
training should set up negative pressure containment areas.
OPERATING INSTRUCTIONS
Setup
1. Unwrap the cord completely.
2. Place the HEPA 700 with the handle up. Ensure that neither
the inlet nor the outlet are obstructed.
3. Plug into a standard 115V GFCI-protected outlet.
4. For additional setup instructions, go to
HEPA700.legendbrandsrestoration.com
Electrical Outlets
You can connect up to eight (8) HEPA 700s on a 15-amp
circuit on the lowest speed; four (4) on the highest speed.
Carry handle.
Folds down when
not in use.
Feet for
horizontal
operation &
stacking.
115V outlets
(×2) and
breaker reset
switch.
Use the hook-and-pile
fasteners to attach the inlet
cover here while unit is use.
1
Filtered air
outlet. Filter
retainer ring may
be used to
attach 14 in.
layflat ducting.
Legend Brands, Inc.