To disable door open detection. (Factory
default)
To enable door open detection
Alarm output time
To set the alarm output time (0-3 minutes)
Factory default is 1 minute
Keypad Lockout & Alarm Output options. If there are 10 invalid cards or 10 incorrect PIN
numbers in a 10 minute period either the keypad will lockout for 10 minutes or both the alarm
and the inside buzzer will operate for 10 minutes, depending on the option selected below.
Normal status: No keypad lockout or
alarm (factory default)
Keypad Lockout
Alarm and inside buzzer operate
To remove the alarm
To reset the Door Forced Open warning
To reset the Door Open Too Long warning Close the door or Read valid card or
The unit operating as a Wigeand Output Reader
In this mode the unit supports a Wiegand 26 bit output so the Wiegand data lines can be
connected to any controller which supports a Wiegand 26 bit input.
6
0
#
6
1
#
5
0~3
#
# (Factory default setting)
7
0
7
1
#
7
2
#
Read valid card or Master Code #
Master Code #
7