Specifications
Technische Daten
Spécifications
Specifiche
Catalog No.
Voltage Range
Référence
Tension
Bestell-Nr.
Spannung
N. Catalogo
Tensione
Referencia
Voltaje
1492-IFM20F, -RIFM20F
0-264 V AC/DC
10-30 V AC/DC
1492-IFM20D24
1492-IFM20D120
85-132 V AC/DC
1492-IFM40F, -RIFM40F
0-132 V AC/DC
1492-IFM40D24, -RIFM40D24
10-30 V AC/DC
0-132 V AC/DC
1492-IFM20FH
1492-RIFM20FH
0-132 V AC/DC
1492-IFM40FH
0-132 V AC/DC
1492-RIFM40FH
0-132 V AC/DC
Ratings when used with 1762-L40AWA, 1762-L40BWA output. (For inputs use 2 Amps current per circuit.)
0-132 VAC
1492-IFM40F, -RIFM40F
10-125 VDC
Ratings when used with 1762-L40BXB output. (For inputs use 2 Amps current per circuit.)
0-132 VAC
10-125 VDC
1492-IFM40F, -RIFM40F
24 VDC
Ratings when used with 1764-24AWA, 1762-24BWA output. (For inputs use 2 Amps current per circuit.)
0-264 VAC
1492-IFM20F, -RIFM20F
10-125 VDC
Ratings when used with 1764-28BXB output. (For inputs use 2 Amps current per circuit.)
0-264 VAC
10-125 VDC
1492-IFM20F, -RIFM20F
24 VDC
Operating Temperature Range
Catalog No.
Plage températures de fonctionnement
Référence
Betriebstemperaturbereich
Bestell-Nr.
Limiti temperatura di funzionamento
N. Catalogo
Rango de temperatura de funcionamient
Referencia
1492-IFM20F, -RIFM20F
1492-IFM20FH, -RIFM20FH
6
1492-IFM20D24
1492-IFM20D120
0° C - 60° C
1492-IFM40F, -RIFM40F
1492-IFM40FH, -RIFM40FH
6
1492-IFM40D24, -RIFM40D24
For transients > 600 Vp use a UL recognized suppression device rated at 2.5 kV withstand.
Pour des transitoires > 600 Vp utilisez un dispositif de suppression certifié UL à 2,5 kV nominal de tenue.
Für Einschaltstöße > 600 Vp verwenden Sie einen UL anerkannten Entstörer, der bewertet wurde bei 2,5 kV standzuhalten.
Per transitori > 600 Vp usare dispositivo di soppressione riconosciuto da UL capace di sopportare 2,5 kV.
Para transitorios > 600 Vp use un dispositivo de supresión reconocido UL clasificado con 2,5 kV.
Non-condensing
Sans condensation
Nicht kondensierend
Senza condensa
sin condensación
Power, input and output (I/O) wiring must be in accordance with Class I Division 2 wiring methods - Artticle 501-10(B)(1) of the National Electrical Code.
WARNING
Explosion Hazard - substitution of components may impair suitability for Class I Division 2.
Explosion Hazard - Do Not Disconnect Equipment unless power has been switched off or the area is known to be Non-Hazardous.
Add 0.39 in. to the width dimension for 1492-Rxx type modules.
No FM certification for this type of modules
6
PN-244749
DIR 40063-185 (Version 22)
Especificaciones
Max. Current/Circuit
Max. Current/Module
Max. Courant/Circuit
Max. Courant/Module
Max. Strom/Schaltkreis
Max. Strom/Modul
Max. Corrente/circuito
Max. Corrente/modulo
Max. Intensidad/circuito
Max. Intensidad/módulo
2 Amps
12 Amps
2 Amps
12 Amps
Out 0 - 3, 2 Amps
12 Amps
Out 4 - 15, 1 Amp
Out 0, 1, 10, 11, 2 Amps
Out 12 - 15, 1 Amp
12 Amps
Out 2 - 9, 0.5 Amps
Out 0 - 3, 2 Amps
12 Amps
Out 4 - 11, 1 Amp
Out 0 - 1, 2 Amps
Out 8 - 11, 1 Amp
12 Amps
Out 2 - 7, 0.5 Amps
Approx. Shipping Weight
Operating Humidity
Poids d'embarquement approximatif
Humidité relative
Ungefähres Versandgewicht
Betriebsluftfeuchtigkeit
Peso approssimativo del carico
Umidità di esercizio
Peso aproximado al momento de
Humedad operativa
embarque
0.62 lb.
3
5 - 95 %
(278 g.)
Indicator Circuit Current
Courant circuit voyants
Strom, Anzeigeschaltkreis
Corrente circuito indicatori
Intensidad del circuito
de indicadores
N/A
2.0mA
2.5mA
N/A
2.0mA
N/A
N/A
N/A
N/A
N/A
Dimensions
Dimensions
Abmessungen
Dimensioni
Dimensiones
Width
5
4.33 in. (110mm)
3.27 in. (83mm)
4.72 in. (120mm)
2.78 in. (70.5mm)
4.33 in. (110mm)
3.27 in. (83mm)
4.33 in. (110mm)
3.27 in. (83mm)
5
4.33 in. (110mm)
3.27 in. (83mm)
4.72 in. (120mm)
2.78 in. (70.5mm)
5
4.33 in. (110mm)
3.27 in. (83mm)
(5)
Maximum Recurring Peak Voltage
Tension de crele réurrente maximale
Maximale periodische Hochstspannung
Tensione massima di cresta ricorrente
Voltaje de cresta iterativo máximo
600 V
600 V
600 V
600 V
600 V
600 V
Standards
Normes
Standards
Standard
Estándares
Height
Depth
cULus (File: E10314, Guide No. NRAG)
Suitable for use in Class 1 Div 2 Groups A, B, C and D
Hazardous and Non-Hazardous Loca ons.
2.78 in.
Temperature Code = T3C at 60°C
(70.5mm)
CE: Compliant for all applicable direc ves
FM Class 1 Div 2 Groups A, B, C and D
Temperature Ra ng T3C = 60°C (J.I. 3000590)
p
p
p
p
p
p
4