Shipper Instructions to Start Logger:
Fill out the shipping information section located below the logger on
1.
the card.
2.
Press and hold the green START
button until the green ACTIVE LED
flashes 5 times.
3.
The logger will enter a factory
programmed 30-minute delay start.
During this period, the green LED
will flash twice every 12 seconds
to indicate it's in delay start mode.
4.
After the delay start time has expired,
the logger begins recording temperature.
During active recording the green LED
will flash once every 12 seconds to
confirm it is in active mode.
5.
Remove peel-away barcode label and
apply to shipping document. Serial
number on logger and barcode label
matches PDF reports for traceability.
6.
Use adhesive strips on back of card
to attach to pallet or package.
7.
Optionally, the logger can be placed inside a carton to track the
temperature of the product.
Receiver Instructions to Stop
Logger and Download Trip Reports
Remove logger from card.
1.
To stop the logger, insert connector
2.
into USB port of Windows PC or tablet
with Adobe Reader, or a compatible
Adobe Reader application
The LEDs will flash alternately red-green
3.
red-green to indicate reports are being generated. Red and green
LEDs will remain lit to indicate PDF and CSV reports are now ready to
be viewed
1
Start Button
ACTIVE LED
Flashes once every 12 seconds in active mode