English
To replace the screw down (6.O), remove the
cap (6.H) and the screw (6.I) and pull out the
lever (6.L).
Remove the cap (6.A), the screw (6.B), the flat
washer (6.C), the knob (6.D), the handle (6.E)
and the spacer (6.F).
Once the plate (6.G) has been removed, screw
on the stop cocks (6.P) in clockwise direction
using a screwdriver, then disassemble the cover
(6.N). Using a wrench, remove and replace the
screw down (6.O). Carefully clean the support
sealing surfaces of the gaskets and reassemble
in reverse order. During the assembly, DO
NOT move the bar of the cartridge so as to not
compromise the calibration.
Make sure to place the spacer (6.M) back on
the new screw down (6.O).
FIG. 07
To replace only the handle and the knob (7.I-7.L)
follow the instructions given below:
Pull out the cap (7.F), loosen the screw (7.G)
and the flat washer (7.H), then remove the knob
(7.I), the handle (7.L) and the spacer (7.M).
DO NOT move the bar of the cartridge (7.O) so
as to not compromise the calibration.
Assemble the new handle and knob (7.I-7.L)
and lock them with the screw (7.G), making
sure to install the spacer (7.M) and the flat
washer (7.H). Complete the installation by
inserting the cap (7.F).
To replace the thermostatic cartridge with the
handle (7.R), turn off the water supply and
follow the instructions given below:
remove the grub screw (7.P) and pull out the
thermostatic cartridge with the handle (7.R).
Install the new assembly (7.R) into the faucet
housing carefully aligning the positioning hole
with the housing of the grub screw (7.P). Tighten
the grub screw without forcing it to prevent
malfunctioning or damages.
To replace only the thermostatic cartridge (7.O)
follow the instructions given below:
Remove the cap (7.A), the screw (7.B) and pull
out the lever (7.C). Extract the cap (7.F), loosen
the screw (7.G) and the flat washer (7.H), then
slide off the knob (7.I), the handle (7.L) and the
spacer (7.M).
Once the plate (7.E) has been removed, turn the
stop cocks (7.Q) clockwise using a screwdriver.
Loosen the grub screw (7.P) and remove the
Based on its policy of steady development Fortis reserves the right to change the characteristics
of the products without notice and therefore the images and data contained in this catalogue may vary.
Istruz. art. 8869000.indd 7
thermostatic cartridge from the assembly; then
remove the lock nut (7.N).
Install the new cartridge (7.O) in the faucet
housing aligning the positioning hole with the
grub screw housing (7.P). Tighten the grub screw
without forcing it to prevent malfunctioning or
damages.
DO NOT move the bar of the new cartridge
(7.O) so as to not compromise the calibration.
Once completed the replacement, turn the
stop cocks (7.Q) counterclockwise using
a screwdriver. Reassemble the plate (7.E),
position the lever (7.C) placing the spacer (7.D)
in between and lock with the screw (7.B), then
complete by installing the cap (7.A).
Install the temperature adjustment lock nut (7.L)
as shown, insert the spacer (7.M), the handle
(7.L), the knob (7.I) and fasten with the screw
(7.G) installing the flat washer (7.H). Complete
by positioning the cap (7.F).
FIG. 08
MAINTENANCE OF THE SURFACES
Before cleaning, make sure the faucet is cold
(heat wears the surface of the faucet down). Do
not use products containing acids or corrosive
substances. Wipe the faucet daily with a soft
cloth. Do not use steel wool or metal pads,
abrasive sponges or similar products. Right
after cleaning rinse off the detergent residues
with cold water. Damages to the faucets caused
by incorrect treatment are not covered by the
warranty.