CAUTION: Do not connect to a water source where water pressure exceeds 120 PSI (8 bar/827 kPa).
This will cause permanent damage to the cooler.
CAUTION: If using an extension cord, do not exceed the cord's amperage ratings. Undersized extension
cords create excessive drops in voltage, causing the electric motor to generate excess heat. This results
in inefficient motor operation and premature motor failure and will void the warranty.
Installing the casters (Cool-Space® 300 only)
1. Locate the package of four (4) casters and sixteen (16) bolts and remove from box.
2. Lay box on its side and carefully open bottom of box. Do not stand box upside down.
3. Install the four casters using the bolts.
4. Stand cooler up on casters and remove box.
The cooler has been factory tested and is ready to use. Place the cooler on level ground with the casters locked
to prevent inadvertent movement.
Connecting the water supply
The cooler comes equipped with a garden hose water source connection. Use a standard garden hose (not
provided) to connect the water supply to the cooler.
Connecting the electrical supply
Plug the cooler into a fused or breaker-protected circuit. Refer to the tables below for circuit size and extension
cord requirements. Cool-Space 500 models cannot be connected to a GFCI outlet.
Amperage and Circuit Requirements
Model
Cool-Space 300
Cool-Space 400
Cool-Space 500
Three-Conductor Heavy Duty Extension Cord Requirements (120 V)
Cord Length
0–50 ft (0–15 m)
50–100 ft (15–30 m)
2
ASSEMBLY AND SETUP
Volts +/- 10%
120 V
220/230 V
120 V
220/230 V
120 V
220/230 V
16 GA
13 A
10 A
WWW.BIGASSFANS.COM
Frequency
Min. Circuit Size
60 Hz
50/60 Hz
60 Hz
50/60 Hz
60 Hz
50/60 Hz
Cord Size
14 GA
18 A
13 A
© 2020 DELTA T LLC
ALL RIGHTS RESERVED.
Running Amps
15 A
10 A
15 A
10 A
25 A
15 A
12 GA
25 A
18 A
4.1 A
1.8 A
8.0 A
5.0 A
16.5 A
8.6 A
10 GA
30 A
25 A