OPERATING YOUR FIXTURE
1. For wall mount, rotate the motion sensor ball up or
down to desired detection pattern (Fig. 2A). For eave
mount, extend the motion arm away from the
coverplate and adjust to desired detection pattern
(Fig. 2B).
2. Rotate TIME knob on bottom of the sensor to
"TEST" (Fig. 6).
3. Turn on the power to fixture. Allow fixture to warm
up approximately 50 seconds before testing. (Lights
will come on during warm-up period.)
4. Aim sensor head toward desired detection area,
maintaining a 5°–15° down angle to allow moisture
to drain.
5. Walk across the detection zone at the farthest
distance you wish your detector to detect motion.
6. Adjust sensitivity knob until you get desired results.
Lights will turn off 4 seconds after all
motion stops.
NOTE: For maximum range performance, allow fixture
to operate in any mode (with power to the unit) for at
least 48 hours.
7. To set the ON time, rotate knob arrow to point to the
desired time setting within the TIME range (up to 12
minutes) (Fig. 7).
ADJUSTING THE COLOR
TEMPERATURE (CCT)
• This product features selectable white color
tuning. Choose between three preset light colors
on the center dial of the base housing before,
during or after installation (fig. 8): 
• These settings are designated by the abbreviations
located on the center dial on the base housing
(fig. 8):
3K = 3000K CCT, or soft white
4K = 4000K CCT, or neutral white
[factory default]
5K = 5000K CCT, or daylight
• Use a flathead or Phillips head screwdriver to rotate
the dial so the arrow points toward the desired
setting.
• DO NOT USE a power tool or over-rotate the dial.
SELECTING YOUR DESIRED FEATURE
Mode of
Operation
Auto Setting (motion activated)
Lights should turn ON with
motion only at night and should
turn OFF according to the
TIME dial setting.
Dusk to Dawn Setting
(activated only at night)
Lights should turn ON for 6 hours
at dusk and then reset to
the Auto Setting.
Test Setting
Lights should turn ON with
motion both day and night.
Lights should turn OFF
after 4 seconds.
Return to Auto Setting
(motion activated)
From any of the above settings
5
6
7
Example of knob arrow
placement to set duration
of ON time.
8
TIME Knob
How to Set
Adjustment
Power Switch
Knob arrow points to
Turn the power
desired time setting
to the fixture ON.
within TIME range.
Knob arrow points to
Turn the power
desired time setting
OFF and ON twice
within TIME range.
within 3 seconds.
TEST
Turn the power
to the fixture ON.
Knob arrow points to
Turn the power OFF
desired time setting
for at least 40 seconds
within TIME range.
and then back ON.

TROUBLESHOOTING

Problem
Cause / Solution
Light does not
No power to the fixture.
come ON with
motion at night.
A
Surrounding external ambient light is too bright. (If so, the unit may
think it is daytime.)
TURN OFF POWER BEFORE CONTINUING
Wiring to the unit is loose.
Light comes ON
There is motion in the detection zone.
for no apparent
reason at night.
Light stays ON at
There is motion in the detection zone.
night and does
not turn OFF.
If there is no motion in the detection zone, unit is in "Dusk to Dawn
Setting" (override mode).
Light
The light given from the unit's own lamp is affecting the
motion sensor.
continuously
blinks ON and
OFF at night.
Light is ON
The controls on the bottom of the motion sensor are in "TEST" mode.
during the day.
The motion detector is shadowed.
Cannot activate
Surrounding external ambient light is too bright. (If so, the unit may
think it is daytime.)
Dusk to Dawn
Setting at night
(override mode).
Not enough time is allowed to enter the "Dusk to Dawn Setting."
There is more than one fixture on an indoor wall switch.
5-YEAR LIMITED WARRANTY
THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES,
WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT LIMITED TO, ANY
WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
Cooper Lighting Solutions ("CLS") warrants to customers that, for a period of five years from
the date of purchase, CLS products will be free from defects in materials and workmanship.
The obligation of CLS under this warranty is expressly limited to the provision of replacement
products. This warranty is extended only to the original purchaser of the product. A
purchaser's receipt or other proof of date of original purchase acceptable to CLS. This is
required before warranty performance shall be rendered. This warranty does not apply to CLS
products that have been altered or repaired that have been subjected to neglect, abuse,
misuse or accident (including shipping damages). This warranty does not apply to products
not manufactured by CLS which have been supplied, installed, and/or used in conjunction
with CLS products. Damage to the product caused by replacement bulbs or corrosion or
discoloration of brass components are not covered by this warranty.
LIMITATION OF LIABILITY:
IN NO EVENT SHALL CLS BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES (REGARDLESS OF THE FORM OF ACTION, WHETHER IN CONTRACT,
STRICT LIABILITY, OR IN TORT INCLUDING NEGLIGENCE), NOR FOR LOST PROFITS; NOR SHALL
THE LIABILITY OF CLS FOR ANY CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH
THESE TERMS OR THE MANUFACTURE, SALE, DELIVERY, USE, MAINTENANCE, REPAIR OR
2
• Check if circuit breaker tripped.
• Confirm wall switch is ON.
• Adjust the sensitivity knob.
• Re-aim the head.
• Relocate or reposition the unit away from the light.
• Check wiring; reconnect if necessary using wire nuts
(E) provided.
• Make sure the sensor is not picking up moving objects such as
trees, traffic, etc.
TEST FOR YOURSELF:
• Cover the sensor lens with cardboard to prevent sensor
from detecting motion. If the light stays off, something in the
detection zone is triggering the sensor.
* If the light stays on with the sensor lens covered, contact
customer service.
• Adjust the sensitivity knob.
• Reposition the sensor.
• Make sure the sensor is not picking up moving objects such as
trees, traffic, etc.
• Adjust the sensitivity knob.
• Reposition the sensor.
• Turn the light switch to the OFF position for 40 seconds, and
then turn back to the ON position. This will send the unit back
into the "Auto" mode.
• Re-aim the lamp.
• Reposition motion sensor.
• Change dial setting (not "TEST" mode).
• Reposition motion sensor.
• Re-aim the head.
• Relocate or reposition the unit away from the light.
• Turn power OFF and ON twice within 3 seconds.
• If so, put them on separate switches.