Danger Of Fire; Connection With The Mains; Operation - EuroLite BLACK FLOODLIGHT UV-Spot Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Caution: Devices in hanging installations may cause severe injuries when crashing down! If you have
doubts concerning the safety of a possible installation, do NOT install the device!
Before rigging make sure that the installation area can hold a minimum point load of 10 times the device's
weight.
When installing the device, make sure there is no highly-inflammable
material (decoration articles, etc.) within a distance of min. 0.5 m.
Mount the device to your trussing system using an appropriate clamp.
For overhead use, always install a safety-rope that can hold at least 12 times the weight of the fixture. You
must only use safety-ropes with quick link with screw cap. Pull the safety-rope through the attachment eyelet
and over the trussing system or a safe fixation spot. Insert the end in the quick link and tighten the safety
screw.
The maximum drop distance must never exceed 20 cm.
A safety rope which already held the strain of a crash or which is defective must not be used again.
Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.
Before taking into operation for the first time, the installation has to be approved by an expert!

Connection with the mains

Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.

OPERATION

After you connected the spot to the mains, the lamp needs 3-4 minutes warm-up time until it reaches full
lighting output.

DANGER OF FIRE!

DANGER TO LIFE!
International
L
N
15/31
5110080A_V_3_2.DOC

Publicidad

Tabla de contenido
loading

Tabla de contenido