C - INSTALLATION

6.2 - ACTUATORS

For actuator wiring, use a 2x1.5mm2 section cable and waterproof junction boxes. For each motor, the
cable length must not exceed 8 m.
• Opening inwards:

6.3 - FLASHING LIGHT

L0
• Connect the flashing light wires to the terminal block as shown in the diagram below and reconnect the
terminal block.
• Use a 2x0.5mm² section cable, at least.
• Maintain the polarity.

6.4 - PHOTOCELLS

• Disconnect the removable terminal block, connect the photocell wires to the terminal block as shown in
the diagram below and then reconnect the terminal block.
1 set of photocells
Photocell RX1
EN
20
L1
L2
L3
L4
-
+
PROG
~-
~+
NO COM NC
* actuator installed on the panel that opens first
+ -
BAT TRANS
OK
~-
~+
+ -
BAT TRANS
Photocell TX1