Descargar Imprimir esta página

Dupla CO2 Armatur Pro Instrucciones De Uso página 4

Ocultar thumbs Ver también para CO2 Armatur Pro:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

CO ² Armatur Pro
Thank you for choosing to purchase the CO ² Armatur Pro. With the CO ² Armatur Pro you have obtained a product of the highest quality
and reliability. Strict and continual quality checks and manufacture according to ISO 9001 ensure a product with a long service life. These
operating instructions are part of the product. They include important information on commissioning and operation. Keep the operating
instructions for future reference.
Special features of the CO ² Armatur Pro:
· high control accuracy through precision pressure reducer
· finely adjustable operating pressure setting
· pressure-tight fine precision needle valve
setting
· large, easily readable working
· integrated overpressure safety valve
· wear-free seal to the cylinder valve
· incl. integrated check valve to protect the CO ² fitting
· corrosion-resistant thanks to material finishing
· fine filter in cylinder connection and fine needle valve
· for all CO ² cylinders with external cylinder valve
· low pressure has factory setting of 0 bar
· optimum operating pressure setting at 1 – 1.5 bar
1
5
Special instructions: Replacing the depot and work on the CO ² Armatur Pro must only be carried out when the device is pressureless.
Starting up: Make sure that the stainless steel needle valve
Insert the cylinder connection
2
ended spanner. Connect the hose connection spout
Completely open the cylinder valve and check the CO ² cylinder pressure on the cylinder pressure gauge
rature. The preset operating pressure (operating pressure gauge
to set a operating pressure of around 1 – 1.5 bar. You can read off the set pressure at the operating pressure gauge
screw on the stainless steel needle valve
pressure adjustment screw
for further fine adjustment of the bubble count. The bubble count is proportional to the defined operating pressure.
6
If you have set a bubble count of around 10 bubbles per minute at a operating pressure of 1 bar, you can double the bubble count simply by
increasing the operating pressure to 2 bar and halve the bubble count by reducing the operating pressure by half. This allows a convenient and
precise bubble count setting. Turn the pressure adjustment screw
4
1
for high-precision bubble count
2
and cylinder pressure gauge
3
5
6
2
6
1
into the opening of the cylinder valve and tighten the union nut
of the CO ² Armatur Pro to the CO ² Reactor or CO ² Atomiser using a CO ² tight hose.
4
to roughly define the desired bubble count. After approx. 1 day (running-in period) you can use
8
4
3
is closed before connecting the CO ² Armatur Pro to the CO ² Depot.
) set by the factory is 0 bar. For initial use, use the pressure adjustment screw 8
7
anticlockwise to reduce the operating pressure.
6
4
3
hand-tight, possible using a 30 mm open-
. This is around 60 bar at room tempe-
5
. Then use the adjustment
7

Publicidad

loading

Este manual también es adecuado para:

80204