Configuration For The Link S88 - Marklin Digital Link S88 Manual De Instrucciones

Ocultar thumbs Ver también para Link S88:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 36

Configuration for the Link S88

The Link S88 must first be configured in the controller
before being used for the first time.
• To do this with the CS2, go to Setup/Info. Here switch to
the configuration mode. Under „Info", you can select the
device that you want to edit. Select here the Link S88 that
has just been plugged in.
• To do this with the CS3, go into the settings using the
„System" button. Here select „System" again. You will
now find a button for the Link S88 in the left column.
The following settings can / must be done:
• Evaluation of Bus 0 (direct bus for the Link S88),
Setting for individual units = 16 indicator contacts
Setting for matrix = up to 64 button controllers
• Length of Bus 1 – 3
Here you enter how many S88 units are connected to
each bus (max. 31).
• Cycle period for Bus 1 – 3
Enter query cycles for the S88 busses in milliseconds (ms)
(min 10 ms - max. 1000 msm, factory setting 100 ms).
• Bit time for the S88
Set the cycle for the answer (factory setting 167 µs)
• Cycle period for (Link S88) Contacts 1 – 16
Query cycles for the Link contacts when used as track
contacts 1 – 16.
• Cycle period for keyboard
Query cycle when used as a keyboard (factory setting 67 ms).
• Columns for the keyboard
Entering the columns (max. 8) for the keyboard matrix
16
• Rows for the keyboard
Entering the rows (max. 8) for the keyboard matrix
Addresses for the S88-Module:
The S88-module automatically get an address when it is
plugged in. You will find below the addresses for settings in
the Central Station.
Contacts (track): 1 – 16
Button controller addresses: 101 – 164
Bus 1: 1001 – 1496 (ex. 1005 = 1st module, Contact 5)
Bus 2: 2001 – 2496
Bus 3: 3001 – 3496
Swapping Devices.
If you need to swap out a device, the new Link S88 can
be reset to the previous device number. Resetting is done
after registering the Link S88 in the CS. Give the new S88
the number of the device it is replacing at „ID". After that,
the CS has to be restarted, and now all of the contacts will
function as usual.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

60883

Tabla de contenido