2 INSTALLATION
2C-5. Ozone Tube Connection - Refer to Figure 3b.
After the system has been set for the correct flow rate, remove the flow
meter assembly and connect the ozone tube between the ozone outlet
barb on the DEL Ozone generator, and the tube adapter on the injector
assembly. Ensure that the check valve arrow is pointing toward the
injector. If equipment is above water level, cut off the excess tubing so
that the line from the injector to the DEL Ozone generator is as straight
and free from dips and loops as possible. If equipment is below the
water level, run tubing to a point above water level. Ensure that all tube
connections are secured with clamps.
2D. Electrical
2D-1. Main Power
This device is intended to be installed by a certified electrical
technician, in accordance with local electrical codes. Connect the DEL
Ozone generator to the pool timing clock so that the DEL Ozone
generator operates simultaneously with the pool pump. The DEL
Ozone generator has three available knockouts for a 1/2 inch conduit
fitting, two on each side and one on the back. Remove only the ideal
knockout and install the proper conduit fitting. Open the enclosure
and locate the terminal block. Connect Line 1, Line 2, and ground
to the terminal block as indicated by the label on the inside of the
enclosure door. Refer to the IMPORTANT SAFETY INSTRUCTIONS at
the beginning of this manual for important wiring information.
2D-2. Earth Grounding Lug
Using an 6 AWG (13.3 mm2) conductor, connect the grounding lug
on the bottom of the DEL Ozone generator to an appropriate earth
contact.