Technical Data - EINHELL LEF 12 M Manual De Instrucciones

Ocultar thumbs Ver también para LEF 12 M:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
Anleitung LEF 12 M_SPK7:Anleitung NLE 20 E_SPK7
GB
Read these instructions carefully and
keep them in a safe place.
Layout (Fig. 1)
1
ON/OFF switch with humidity control
2
"Power" LED
3
"W.F." LED for condensate collector full
4
Recessed grip
5
Housing front
6
Housing rear
7
Air inlet grille with air filter
8
Connection for condensate drainage hose
9
Condensate collector
10 Roller
11 Mains cable

Technical data

Power supply:
230 V ~ 50 Hz
Max. rated current consumption:
Starting current:
Max. power consumption:
Sound pressure level:
≤ 44 dB(A)
Dehumidifying capacity:
0.5 l/h (at a room temperature of 30°C and air
humidity of 80%)
0.2 l/h (at a room temperature of 27°C and air
humidity of 60%)
Operating range for humidity
Operating range for temperature:
Max. air flow volume:
Volume of condensate container:
Coolant:
Coolant quantity:
Appliance dimensions:
310 x 520 x 260 mm
Appliance weight:
Features
The unit switches off automatically once the set
humidity is attained and switches on once the set
humidity is exceeded.
The unit switches off automatically as soon as the
condensate collector is full.
Constant condensate drainage can be set.
6
Operating principle
Condensor
Evaporator
Humid
air
Condensed
water tank
The dehumidifier controls the relative humidity of the
inlet air. The humid air condenses on the cooler
elements and is transferred to the water tank. The
dry air is heated a little on the condenser and
returned to the room.
1.5 A
6.3 A
Scope of use
240 W
The dehumidifier is designed for private use only
(e.g. for living rooms, bedrooms, bathrooms,
storage areas, laundry rooms or cellars).
Note:
70% air humidity is the upper limit with which the
human body feels comfortable. If it is too warm for
40-80%
the human body this means the water content is too
8 -32°C
high, i.e. humidity is too high. Humidity has a certain
relationship to temperature. As a general rule, the
130 m
3
following applies: 60-70% for the summer and 50-
3.8 liters
70% for the winter.
R134a
200 g
At room temperatures of below 10°C or a relative
room humidity of below 40% it will not be
economical to use the appliance.
13.5 kg
Before using
The room temperature should lie in the range
from 8 to 32°C/RH 40-80%. The dehumidifier will
not work effectively outside this range.
Important safety informations:
The dehumidifier should always be used in
vertical position.