InStALLAtIon And coMMISSIonInG
5
7
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
4
3
Fig. 3
8
6
Fig. 4
Fig. 5
Plug in the 2 pole male connector (6) in the 2 pole female
connector (7) of the unit.
Data and power bus connection
strip the end of the Can Bus cable (381954) according to
the scheme shown in figure 6.
Connect each wire of the Can Bus cable to the 5 pole
male plug (951982) according to the scheme shown in
figure 7.
nOTe: Depending on installation layout, it may be
possible that in one of the 5 pole plugs, the power wires
(red/black) must be left unconnected
attach the cable to the plastic housing (951893), screw
the retaining plate (10) and close the housing.
Plug in the 5 pole connector (8) in either of the 5 pole
female connectors of the unit. in case that only one male
connector is connected, use the bottom female socket.
Plug into the upper female socket of the unit the
protection cap (11).
EN
Fig. 6
3
R. 12/18 838 841