CHARAKTERYSTYKA URZĄDZENIA
Submersible pumps are household appliances. They are designed to pump clean and slightly contaminated water from reservoirs
in an intermittent working cycle. Acceptable time of continuous operation is 2 hours, and then work must be interrupted for at
least 20 minutes. The total working time in such cycles should not exceed 12 hours. By no means is it permitted to pump other
liquids than water, such as oils, gasoline, solvents, acids, bases, organic substances, fats, wastewater, faecal matter or water
contaminated with other substances. The pumped water should not contain mechanical contaminants or other abrasive particles.
Pumping contaminated water is acceptable solely when special precautions have been taken and if the pumping process is being
continuously controlled.
Attention! Any interruptions of the fl ow of water through the pump may lead to its irreversible damage!
The pump has been designed exclusively for household applications. It is prohibited to use the pump for professional and com-
mercial purposes. A correct, reliable and safe functioning of the appliance depends on its correct operation, so:
Before you proceed to work with the device, read thoroughly the operating manual and keep it for further reference.
The supplier will not be held responsible for any damage caused by failure to observe safety regulations and the recommenda-
tions included in this manual.
EQUIPMENT
The original factory box contains a pump with a socket ferrule to connect a hose. The pump is not supplied with a pumping conduit
(hose).
TECHNICAL PARAMETERS
Parameter
Pump type
Power supply voltage
Power supply frequency
Nominal power
Insulation class
Protection grade (IP)
Maximum capacity
Water outlet diameter (in.)
Water outlet diameter (out.)
Maximum head
Maximum immerse depth
Cable length
Maximum water temperature
Net weight
Work mode
Attention! In order to ensure the maximum effi ciency of the appliance, connect to the pump a hose whose diameter corresponds
to the maximum diameter of the water connection. According to the table, the pump performance decreases with increasing
delivery height. The effi ciency drop can also be observed as the length of the hose increases, even if there is no increase in the
delivery height.
O
P
8
Head high [m]
0
12
24
36
48
60
68
E
R
A
T
I
GB
Measure unit
[V~]
[Hz]
[W]
[dm
/h]
3
["]
[mm]
[m]
[m]
[m]
[
o
C]
[kg]
N
G
M
A
Value
79943
220 - 230
50
280
I
IPX8
1020
1/2
19
68
5
10
35
3,9
S3 (max. 2 h on, min. 20 min off : tot. 12 h on)
Pump type
79943
Capacity [dm
/h]
3
1020
950
850
700
500
300
100
N
U
A
L