If you press the [POWER] switch before the time has expired, the time programming is deleted, the
TRANSFORM unit switches on and can be operated in the required operating mode.
Residual time: This function is used to automatically deactivate the TRANSFORM unit when the time
entered has expired. Proceed as follows:
a) Press the [TIMER] switch during operation and enter the required number of hours after which the
TRANSFORM unit is to switch off.
b) After the flashing of the number of hours on the LED has stopped, you can select the required function
(cooling, heating, dehumification) and the required temperature.
c) When the set number of hours has expired, the TRANSFORM unit switches on automatically.
If you press the [POWER] switch before the time has expired, the Timer programming is deleted and the
TRANSFORM unit switches off.
8.
[SLEEP]
Using this key you can set the sleep function of the TRANSFORM unit. The microprocessor integrated in
the TRANSFORM unit will raise the pre-set temperature by 2°C per hour up to a maximum of 4°C after 2
hours and maintain this temperature until the set time has expired.
If you use the sleep function, first set the time switch to the set hours as described in the functions
Residual time or Starting time. Then press the [TIMER] switch until the required hours appear on the
display. After the hour display, the display switches automatically to the previous set temperature display.
To change the temperature, press the switch [TEMP+] or [TEMP-]. With each press on the switch, the
temperature increases or decreases by 1°C.
COOLING
 We recommend starting TRANSFORM early in the morning on warm days to get a cool room.
 This TRANSFORM unit has a self-evaporation function for condensation water, so that it is normally
not necessary to empty the water tank in cooling mode. The drainage hose need not be connected.
Please make sure that the outlet is closed with the rubber cap during operation.
(This does not apply in the case of high air humidity. If the TRANSFORM unit operates in cooling mode for a
longer period and especially at a time of year with high air humidity, the condensation tank may be full. The
control lamp will remind you to empty the water. Refer to error message E4. In such a case, empty the water
tank via the condensation water outlet. If continuous high air humidity is likely, it is recommended to drain the
condensation continuously via the drainage hose.)
COOLING IN INDOOR OPERATION
The TRANSFORM unit stands in the room to be cooled.
Connect the air hose and the air outlet grid to the TRANSFORM unit as displayed in the illustration; the air
hose connection piece and air outlet grid need to be exchanged.
The warm extract air must be emitted from the room via the air hose. This can be executed e.g. via a tilted
window, a door or wall aperture. Make sure that no warm outside air can enter the room. For effective
cooling, we recommend our selection of various accessories which reduce or prevent entry of warm air
into the room.
Set the function to „COOLING". Set the target temperature using the temperature control. The settable
temperature range is between 17°C and 30°C target temperature. The TRANSFORM unit must only be
used in an ambient temperature of maximum 35°C.
Note: After switching on, or over, the ventilator operates, but the compressor only starts after the control lamp has
flashed for 3 minutes. Cooling effect may require a further 10 minutes. Further information is available under the item,
„Troubleshooting".
COOLING IN OUTDOOR OPERATION
The TRANSFORM unit is outside the room to be cooled.
Connect the air hose and the air outlet grid to the TRANSFORM unit as displayed in the illustration; the air
hose connection piece and air outlet grid need to be exchanged.
18