is the reduce flame button for the left had side of the appliance. Press this to reduce the height/intensity of your
flame. You will hear an audible beep when you reach the minimum level
is the increase flame button for the left had side of the appliance. Press this to increase the height/intensity of
your flame. You will hear an audible beep when you reach the maximum level
is the reduce flame button for the right had side of the appliance. Press this to reduce the height/intensity of your
flame. You will hear an audible beep when you reach the minimum level
is the increase flame button for the right had side of the appliance. Press this to increase the height/intensity of
your flame. You will hear an audible beep when you reach the maximum level
BLUETOOTH REMOTE CONTROL
The remote control is supplied with 2xAAA batteries. Remove the battery cover from the underside of the remote control
and after removing the batteries from the plastic wrapping fit them into place. Replace the battery cover.
The remote control has BlueTooth technology and is required to be paired to the BlueTooth receiver. This is done
by pressing the
button on Button Panel 'A', the LED's will start to blink on and off. This is to let you know that the
appliance is ready to connect to the remote control. Press the
off. Now the remote control is paired to the appliance.
The operation of the remote control is the same as described in 'Receiver Controls'. You can pair multiple products to
the one remote control by repeating the pairing operation as above on your subsequent products.
The operation of the remote control is the same as described in 'Bluetooth Receiver Controls'.
Maintenance

GENERAL TIPS

Only use filtered tap water in this appliance.
Always ensure that the appliance is sitting on a level surface.
If you intend not using the appliance for longer than 2 weeks, remove and empty the sump and water tank.
Once installed, never move this appliance or lay on its back, without draining the water from sump and water tank.
CLEANING
Warning – Always press Switch 'A' to the 'OFF' (0) position (Fig.10) and disconnect from the power supply before clean-
ing the fire.
We recommend cleaning the following components once every 2 weeks, particularly in hard water areas:-
Water Tank, Sump, Nozzle, Tank cap and seal, Air filter.
For general cleaning use a soft clean duster – never use abrasive cleaners.
To remove any accumulation of dust or fluff the soft brush attachment of a vacuum cleaner should occasionally be used
to clean the outlet grille of the fan heater.
Water tank
1. Remove water tank, as described earlier, put into sink and empty water.
2. Using the supplied brush gently rub the inside surfaces of the cap paying particular attention to the rubber ring in
the outer groove and the centre rubber seal.
3. Put a small quantity of washing up liquid into the tank, refit the cap and shake well, rinse out until all traces of washing
up liquid are gone.
4. Refill with filtered tap water only, replace the cap, do not overtighten.
Sump
1. Press Switch 'A' to the 'OFF' (0) position
2. Gently lift out the fuelbed and place carefully on the ground.
3. Remove the water tank by lifting upwards.
4. Disconnect the electrical connector, located on the right side of the sump. (Fig.5) .
5. Release the right sump locking tabs by turning 90º. This allows the sump to be lifted completely from its location. (Fig.
11)
6. Gently lift up the sump, taking care to keep level so as not to spill any water. Sit the assembly in the sink.
7. Release the left sump locking tabs by turning 90º, then lift off the Nozzle. (Fig.3)
8. Lift out the transducer and carefully tilt, as shown, so that the liquid drains out of the sump. (Fig.13)
9. Put a small amount of washing up liquid into the sump, and using the supplied brush, gently clean all surfaces in the
sump and gently clean the transducer including the metal discs located in the top grooved surface. (Fig.14)
10. When cleaned, thoroughly rinse the sump with clean water to remove all traces of washing up liquid.
11. Clean the Nozzle with the brush and flush out thoroughly with water. (Fig.15)
12. Reverse the above steps to reassemble.
Transducer
The transducer is a consumable item and may need to be replaced through time, depending on its usage. Replacement
transducers can be purchased from our website http://spares.dimplex.co.uk. The transducer is fixed in the sump with a
button on the remote control. The appliance will switch