3.11.7 Selection OF INRUSH function

This is done in function A (AC, AC+DC) by pressing first on
the MIN/MAX key then on the yellow key.
Consultation of the values corresponding to this function is
possible by pressing first on the HOLD key then by short
successive presses on the yellow key (see § 3.7) .
Quitting this function is possible by short presses on the MIN/
MAX key.
3.11.8 Choice of units (°C or °F) in measurement
of temperature
This is done when the temperature function is selected by
short presses on the yellow key, enabling the selection of °C
or °F as applicable. This unit is not memorised when the clamp
is stopped. See § 3.11.9 if you wish to memorise this unit.
3.11.9 Memorisation of unit (°C or °F) in measurement
of temperature
Hold the yellow key pressed and bring the rotary switch from
the OFF position to the T° position.
The unit emits a double beep then the T° symbol goes ON
and the °F symbol flashes if the unit was previously in °C or
the °C symbol flashes if it was in °F.
The selected configuration is memorised when the key is
released: the °F or °C symbol is then on steady.

3.11.10 Suppression of automatic stop

Hold the HOLD key pressed and bring the rotary switch from
the OFF position to the position
The unit emits a double beep then the
The selected configuration is memorised when the key is
released: the
The unit returns to automatic stop mode when the switch
goes to the OFF position.

3.11.11 Activation of the V-Live function

Hold the HOLD key pressed and bring the rotary switch from
the OFF position to the V position.
The unit emits a double beep then the V and
flashes.
The selected configuration is memorised when the key is
released: the V symbol is then ON steady and the
flashes.
Proceed in the same way to suppress the V-Live function: the
symbol then goes OFF when the key is released.
3.11.12 Modification of audio indication threshold in
continuity test
Hold the Yellow key pressed and bring the rotary switch from
the OFF position to the position
The unit beeps, the Ω and
threshold value (40.0 by default) .
symbol remains lit continuously.
P
40
.
symbol flashes.
P
.
symbols go ON along with the
symbol
symbol