5 Putting into operation
1
2
3
4
Fig. 5
Carry out the following activities:
1 Connect coolant supply (1) and coolant return (2) to ABIDRIVE CW (3).
2 Connect coolant supply (4) and coolant return (5) to coolant recirculator (6) .
This completes the connection of the coolant.
5.5 Connecting the control lead
Fig. 4 Overview of connections and operating elements on page EN-9
Carry out the following activities:
1 Connect the control lead (torch side) to connection X1.
2 Connect the control line (intermediate cable assembly) to plug X3 (5) .
This completes the connection of the control lines.
5.6 Mains connection
Dangerous voltage
Electric shock caused by incorrectly installed and damaged cables. For the complete duration of work:
• Check all live cables and connections for proper installation.
• Replace defective, deformed or worn parts.
NOTICE
• For the mains voltage and the fuse protection, please refer to the technical data or the nameplate.
Fig. 4 Overview of connections and operating elements on page EN-9
1 Insert plug socket (3) into connection X2 (4) .
2 Plug in mains plug (16) .
The ABIDRIVE CW is ready for operation.
EN - 10
1
7
6
Cable assembly coolant supply
Cable assembly coolant return
ABIDRIVE CW
Intermediate cable assembly coolant supply
Connecting the coolant
DANGER
2.6 Nameplate on page EN-5
2.6 Nameplate on page EN-5
TIG cold wire feeder
2
3
4
5
Intermediate cable assembly coolant return
5
Coolant recirculator
6
Cable assembly
7