INSTALLATION INSTRUCTIONS fOR pp100A
Carton Contents
•
1 Blower Accessory
•
4 #10 Screws
•
2 #8 Screws
•
1 Lower Baffle
•
1 Medium Upper Baffle
•
1 Large Upper Baffle
NOTICE: Only install this blower
in the heater models listed on the
blower Carton. The thermostat
function will not work correctly in
other heater models.
NOTICE: If wall mounted, discon-
nect heater from gas supply and
remove from wall before install-
ing blower accessory. Contact
a qualified service person to do
this. Follow all local codes.
WARNING: Blower acces-
sory must be grounded. Blower
comes with a three-prong,
grounding plug as shown in Fig-
ure 1. The plug is your protection
against electrical shock. Plug
it into a standard, three-hole,
grounded, outlet. If cord needs
replacing, use only a cord with a
three-prong, grounding plug.
CAUTION: Label all wires
prior to disconnection when
servicing controls. Wiring errors
can cause improper and danger-
ous operation.
ATTACHING BLOWER
ACCESSORY
1.
Remove front panel from heater by re-
moving four screws holding front panel
to cabinet.
Save this manual for future reference/Guarde este manual para referencias furturas.
TheRmOSTAT bLOweR ACCeSSORy
2.
Remove upper baffle (see Figure 3) by
removing 2 screws for medium cabinet
and 3 screws for large cabinet from the
back panel (see Figure 2).
3.
Discard old baffle and replace with new
upper baffle using screws that secured
the old baffle to the cabinet.
4.
Remove knockout plate from cabinet
back panel (see Figure 4).
5.
To remove knockout plate from baffle,
snip two small tabs in front of plate. Move
plate up and down as shown in Figure
4 until tabs in back snap apart. Discard
knockout.
6.
Locate new lower baffle from packaging.
Attach to upper baffle with 2 #10 screws
as shown in Figure 4.
7.
Thread power cord through knockout
hole in back panel.
CAUTION: Do not plug power
cord into electrical outlet until
installation is complete.
Grounded
Outlet
Figure 1: Grounding Plug
Knock Out
Back
Panel
Figure 2: Rear of Heater, Screws and
Blower Location
Blower Location