Troubleshooting - Silverline 427558 Manual Del Usuario

Pistola de engrase neumática 400 cm3
Ocultar thumbs Ver también para 427558:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 22
GB

Troubleshooting

Problem
Tool operating slowly
Tool seized
Tool will not stop after trigger is
fully released
Gun fails to operate
No grease dispensed
Low amount of grease being
dispensed
8
Possible Cause
Pressure incorrect
Dirt within the mechanism
Air blockage
Air leak
Blockage in gauze mesh filter
Dirt or rust in mechanism
Dirt or rust in mechanism
Dirt or rust in mechanism
Throttle valve O-ring or valve seat damaged
Air pocket
Plunger mechanism not released
Compressor pressure low
Grease level in chamber low
If the above troubleshooting solutions fail, contact your dealer or an authorised Silverline service centre.
Solution
Set the correct air pressure according to the specification
Pour oil into air inlet as per maintenance instructions
Operate tool in short bursts to clear blockage
Check all fittings and hose for air leaks and correct issue by re-tightening, using
PTFE tape or replacing
Remove Quick Connector (4) and clean mesh filter
Try 'Tool operating slowly' solutions
Tap tool gently with a soft mallet
Free mechanism by rotating drive manually when disconnected from air line
Have the tool repaired at an authorised Silverline service centre
Follow 'Bleeding the grease chamber' instructions above
Press the Plunger Release (6)
Increase compressor air pressure within the range specified in 'Specifications'
Re-fill chamber

Publicidad