After installing the modules use the TPE to program them.
Connect the TPE to one of the HEADEND's interconnecting modules, wait until the TPE
checks all the modules and then start the search for the module to be programmed.
(For more details see "rack mounting" operating instructions).
The green LED of the module being programmed blinks. The interconnecting module of
the row being programmed displays a blinking number.
The modulators programming menu is shown below.
Important: Push the S button on the TPE to save the set parameters. If you do not
push the S button within 5 minutes of the last change the data set will be lost.
Visualization of
SOFTWARE VERS.
software version
Setting input
INPUT
parameters
Setting output
parameters
OUTPUT
see 2.0
1.0 MODULATOR
SIG7280 VERS.0.0
0,7
VIDEO IN LEV.
0,5
L. AUDIO IN LEV.
0,5
R. AUDIO IN LEV.
11
Input video signal level
0,7 ..1,4 Vpp
1,4
adjustable to different
step 0,1V
sources
Input audio left signal
0,5 ..2,0Vpp
2
level adjustable to
step 0,1V
different sources
Input audio right signal
0,5 ..2,0 Vpp
2
level adjustable to
step 0,1V
different sources