6.6.1 Status LEDs at the PA-4000RC
In addition to the LEDs BUSY and TALK described
above, the zone-paging microphone is equipped
with the following status LEDs:
POWER / CPU ERROR (40) – lights up as soon as
the supply voltage is available; it flashes in
case of a malfunction of the microprocessor
in the PA-4000RC
MIC FAULT / LOW VOLTAGE (41) – lights up
with a failure of the microphone, it flashes
if the supply voltage is too low; in case the
supply voltage is too low, the connection of
an additional power supply unit may help
(
☞
chapter 5 .5 .2, item 3)
SIGNAL (42) – lights up when a microphone
signal is available
EMER . (50) – (one for each PA zone)
light up when an emergency microphone
unit PA-4000FMP signals an emergency sit-
uation for the corresponding zone
6.6.2 Adjustments at the PA-4000RC
The DIP switch block (45) with the three switches
on the rear side of the desk microphone offers
the following functions:
CHIME – in position ON, a chime sounds first
when the TALK button (52) is pressed; the
sound of the chime is the same as if activated
via a momentary pushbutton connected to
the amplifier . It can be selected in the ampli-
☞
fier (
chapter 5 .8 .1)
PRIORITY – in position ON, the PA-4000RC takes
priority over others without this function
activated and it is able to interrupt their
announcements
COMPRESSION – in position ON, the dynamic
power of the microphone signal is attenu-
ated and thus distortions are reduced when
talking at high volume
7
Protective Circuits and
Fault Indication
The output amplifiers of the PA-40120 are
equipped with protective circuits against over-
load and overheating to prevent damage to the
speakers and the amplifier . In case an output
amplifier fails in this way, a relay will switch the
100 V speakers to a connected reserve amplifier
☞
(
chapter 5 .10) . The Protect LED (3) of the
output concerned lights up and a warning signal
sounds via the internal speaker (7) . In addition,
the relay FAULT (18) responds and is therefore
able e . g . to control an external warning facility .
Short lighting-up of all PROTECT LEDs when
switching on the amplifier is usual and does not
indicate any defect .
If a fault occurs at a connected emergency
microphone unit PA-4000FMP (e . g . at the hand-
held microphone of the microphone system),
likewise a warning signal sounds via the internal
speaker (7) and the relay FAULT (18) responds .
In addition, the LED EMER . FAULT (3) of the PA
zone the emergency microphone unit is assigned
to lights up .
In order to be able to hear the warning sig-
nal via the internal speaker (7), the speaker must
be switched on [switch SPEAKER (5) engaged] .
The control LEVEL (6) has no effect on the vol-
ume of the warning signal .
8
Specifications
8.1 Amplifier PA-40120
RMS output power:
4 × 120 W
Peak output power:
4 × 170 W
Frequency range:
45 – 20 000 Hz (−3 dB)
S / N ratio
via LINE input:
> 90 dB (A filter)
via MIC input:
> 70 dB (A filter)
THD:
< 1 % (1 kHz)
Inputs CH 1 – CH 3
XLR / 6 3 mm jack
(input sensitivity, impedance, type of connection)
"MIC":
2 5 mV, 5 kΩ, balanced
"LINE":
245 mV,15 kΩ,
balanced
Inputs CH 4 – CH 5
RCA jacks:
245 mV,15 kΩ,
unbalanced
Input PAGING:
245 mV,10 kΩ,
balanced
Output REC OUT:
775 mV, 3 kΩ,
unbalanced
Output MONITOR:
775 mV, 200 Ω,
unbalanced
Outputs PRE OUT:
775 mV, 200 Ω,
balanced
Output FAULT:
relay with
switch contact
(24 V/ 500 mA max )
Outputs 24 V⎓ EMER OUT: 24 V/ 200 mA
to switch emergency
priority relays
Tone controls
BASS:
± 10 dB / 100 Hz
TREBLE:
± 10 dB / 10 kHz
Power supply
Mains operation:
230 V/ 50 Hz
Power consumption:
1500 VA max
⎓ 24 V
Emergency supply:
Current consumption:
40 A max
Ambient temperature:
0 – 40 °C
Dimensions (W × H × D):
482 × 90 × 377 mm,
2 rack spaces
Weight:
22 1 kg
All rights reserved by MONACOR
may be reproduced in any form or by any means for any commercial use.
Pin configuration
of the input jacks CH 1 to CH 3 (28)
XLR
6 3 mm connector
Pin configuration of the jack MONITOR (26)
6 3 mm connector
8.2 Zone-paging microphone
PA-4000RC
Power supply:
Current consumption
Operation:
Stand-by:
Audio output
Rated level:
Impedance:
Type of connection:
THD:
S / N ratio:
Frequency range:
Dimensions (W × H × D):
Weight:
Connection:
RJ 45
Max number of units:
Total connection length:
Note: For a total cable length above 500 m or if more
than 10 PA-4000RC units are connected, an addi-
tional power supply unit is required for power supply .
Subject to technical modification .
®
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual
1 = ground
2 = signal + (+15 V phantom power)
3 = signal − (+15 V phantom power)
T = signal +
R = signal −
S = ground
T = signal
S = ground
⎓ 24 V (16 – 35 V) via
PA-40120 or PSU
63 mA
57 mA
245 mV
600 Ω
balanced
< 0 5 %
> 60 dB
150 – 15 000 Hz
(−3 dB)
110 × 48 × 155 mm
700 g
32
1000 m max
15