Troubleshooting
Problem
The pump does not start or run.
The pump does not prime.
The flow rate is too low.
Possible Cause
1. The fuse is blown.
2. The breaker is tripped.
3. The plug is disconnected.
4. The plug is corroded.
5. The brushes are worn.
6. The motor is overheated.
1. The suction line is air leaked.
2. The impeller is clogged.
3. The impeller is worn or damaged.
4.The impeller is dry.
1. The hose is kinked or coiled.
2. The strainer or hose is blocked.
3. The discharge hose is too long.
4. The impeller is worn.
8
Corrective Action
1. Replace the fuse.
2. Reset the breaker.
3. Secure the plug.
4. Clean the plug prongs.
5. Replace the brushes.
6. Unplug the power and wait for 30
minutes, then plug in the power cord.
1. Repair suction line by tightening hose
connection or replacing hose washer
if necessary.
2. Remove the blockage.
3. Replace the impeller.
4. Add water to the pump inlet.
1. Straighten the hose.
2. Clean the strainer or hose.
3. Shorten the hose (50 ft. max).
4. Replace the impeller.